Impact of Tower Grounding Resistance on Insulator Flashover Risk in 500 kV HVDC Transmission Systems Under Lightning Strikes

High Voltage Direct Current (HVDC) transmission lines are vulnerable to lightning strikes, which can greatly affect tower performance. This study utilizes PSCAD electromagnetic transient simulations to analyze the transient behavior of a 500 kV HVDC tower under two lightning strike scenarios: (a) shielding wire, and (b) phase conductor. Both scenarios investigated the influence of varying tower grounding resistance and its effect on insulator flashover risk. The model incorporates realistic parameters for shielding wires, tower conductors, insulators, and back flashover. Detailed evaluation of the transient response reveals that increasing grounding resistance leads to higher induced voltage across insulators for both scenarios, consequently elevating the risk of flashover events. Optimal lightning protection is achieved when tower grounding resistance is maintained between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$80-100 \Omega$</tex>. These findings highlight the critical role of effective grounding for reliable HVDC operation during lightning events.

Authors

Institutions

Publication Details

Published
2025-06-17
DOI
https://doi.org/10.1109/apl65034.2025.11108863
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Tower Grounding Resistance on Insulator Flashover Risk in 500 kV HVDC Transmission Systems Under Lightning Strikes

Noradlina Abdullah, Shirley Anak Rufus, Sharifah Masniah Wan Masra, Nazreen Junaidi et al.
1 links
Lightning and Electromagnetic Phenomena
article

Impact of Tower Grounding Resistance on Insulator Flashover Risk in 500 kV HVDC Transmission Systems Under Lightning Strikes

Noradlina Abdullah, Shirley Anak Rufus, Sharifah Masniah Wan Masra, Nazreen Junaidi, Noor Azlinda Ahmad, Dayang Syahirah Binti Awang Shebli
article en

Abstract

High Voltage Direct Current (HVDC) transmission lines are vulnerable to lightning strikes, which can greatly affect tower performance. This study utilizes PSCAD electromagnetic transient simulations to analyze the transient behavior of a 500 kV HVDC tower under two lightning strike scenarios: (a) shielding wire, and (b) phase conductor. Both scenarios investigated the influence of varying tower grounding resistance and its effect on insulator flashover risk. The model incorporates realistic parameters for shielding wires, tower conductors, insulators, and back flashover. Detailed evaluation of the transient response reveals that increasing grounding resistance leads to higher induced voltage across insulators for both scenarios, consequently elevating the risk of flashover events. Optimal lightning protection is achieved when tower grounding resistance is maintained between <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$80-100 \Omega$</tex>. These findings highlight the critical role of effective grounding for reliable HVDC operation during lightning events.

X-Fab (Germany) (DE), Universiti Malaysia Sarawak (MY), University of Technology Malaysia (MY)
Affordable and clean energy
Openalex Percentile: Top 85%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.