Failure Risk Assessment of Medium-Voltage Distribution Lines in the Central Area of Japan

In the Chubu area of Japan, where major industries are densely located, medium-voltage distribution lines are designed to provide high lightning protection to enhance power supply reliability. However, minimizing investment costs is essential to maintain these medium-voltage distribution lines. We analytically assess the lightning performance of distribution lines in low-power-demand areas using XTAP, specifically when middle-phase arcing horns are omitted. In addition, we evaluate the effects on the risk of lightning damage for poles lacking lightning protection equipment when threephase transformers are removed, in response to changing customer needs. Using data on the frequency of lightning strikes and the cumulative frequency distribution of lightning current peaks in the Chubu area, we assessed the risk of multiphase flashover occurrence and the failure risk of the lightning-arrester elements, finding both measures to be effective.

Authors

Institutions

Publication Details

Published
2025-06-17
DOI
https://doi.org/10.1109/apl65034.2025.11108836
Primary Topic
Power Systems and Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Failure Risk Assessment of Medium-Voltage Distribution Lines in the Central Area of Japan

Hidekazu Tanaka, Shinji Yasui, Shoichi Onda, S. Imai et al.
Power Systems and Technologies
article

Failure Risk Assessment of Medium-Voltage Distribution Lines in the Central Area of Japan

Hidekazu Tanaka, Shinji Yasui, Shoichi Onda, S. Imai, Ippei Mizutani
article en

Abstract

In the Chubu area of Japan, where major industries are densely located, medium-voltage distribution lines are designed to provide high lightning protection to enhance power supply reliability. However, minimizing investment costs is essential to maintain these medium-voltage distribution lines. We analytically assess the lightning performance of distribution lines in low-power-demand areas using XTAP, specifically when middle-phase arcing horns are omitted. In addition, we evaluate the effects on the risk of lightning damage for poles lacking lightning protection equipment when threephase transformers are removed, in response to changing customer needs. Using data on the frequency of lightning strikes and the cumulative frequency distribution of lightning current peaks in the Chubu area, we assessed the risk of multiphase flashover occurrence and the failure risk of the lightning-arrester elements, finding both measures to be effective.

Nagoya Institute of Technology (JP), Chubu Electric Power (Japan) (JP)
Openalex Percentile: Top 81%
Power Systems and Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.