Simulation of Overvoltage in Photovoltaic Energy Storage System Caused by Lightning Strike

The photovoltaic energy storage system (PESS) plays an important role in addressing energy dependency issues and promoting the transformation of energy structures. However, lightning strike is one of the main causes of damage to PESS, posing serious threats to its safe operation. This paper constructs a PESS transient model by using PSCAD/EMDTC simulation software to investigate this issue. The distribution of lightning overvoltage in the PESS is calculated. The influence of different lightning strike locations and types on the overvoltage levels of PESS is analyzed. Based on the analysis, lightning protection measures are proposed. The results indicate that when the grid side of the PESS is struck by lightning, the peak overvoltage of the transformer is higher than that when the photovoltaic side is struck. In the case of direct lightning strike, the photovoltaic side can generate a lightning overvoltage with the amplitude of 270.3 kV. The installation of lightning protection equipment effectively suppresses overvoltage.

Authors

Institutions

Publication Details

Published
2025-06-17
DOI
https://doi.org/10.1109/apl65034.2025.11108730
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation of Overvoltage in Photovoltaic Energy Storage System Caused by Lightning Strike

Xiaoyan Bian, Qibin Zhou, Jiawei Shen, Ying Zhang et al.
Power Systems and Renewable Energy
article

Simulation of Overvoltage in Photovoltaic Energy Storage System Caused by Lightning Strike

Xiaoyan Bian, Qibin Zhou, Jiawei Shen, Ying Zhang, Yumin Song, Ruixuan Chen
article en

Abstract

The photovoltaic energy storage system (PESS) plays an important role in addressing energy dependency issues and promoting the transformation of energy structures. However, lightning strike is one of the main causes of damage to PESS, posing serious threats to its safe operation. This paper constructs a PESS transient model by using PSCAD/EMDTC simulation software to investigate this issue. The distribution of lightning overvoltage in the PESS is calculated. The influence of different lightning strike locations and types on the overvoltage levels of PESS is analyzed. Based on the analysis, lightning protection measures are proposed. The results indicate that when the grid side of the PESS is struck by lightning, the peak overvoltage of the transformer is higher than that when the photovoltaic side is struck. In the case of direct lightning strike, the photovoltaic side can generate a lightning overvoltage with the amplitude of 270.3 kV. The installation of lightning protection equipment effectively suppresses overvoltage.

Shanghai University (CN), Shanghai University of Electric Power (CN)
Affordable and clean energy
Openalex Percentile: Top 79%
Power Systems and Renewable Energy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.