Frequency-Domain Analysis of Contaminant Effects on Leakage Current and Harmonic Distortion for Transmission Line Diagnostics

Environmental contaminants such as dust, moss, and flashover residue significantly impact the performance of highvoltage ceramic insulators by altering dielectric properties and increasing leakage current (LC). This study investigates the effect of natural contamination using Fast Fourier Transform (FFT) and harmonic analysis on insulators exposed to realworld conditions in Payakumbuh Koto Panjang. The results indicate that dominant frequencies remain near 50 Hz, with minor shifts (49.95 Hz for moss, 50.06 Hz for dust), highlighting their sensitivity to environmental variations. Magnitude analysis reveals that dust contamination exhibits the highest dominant magnitude (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1.54 \times 10^{-4}$</tex>), indicating stronger energy retention, while harmonic analysis up to the fifth order shows that dust contamination induces the most significant distortions. Flashover residue exhibits a unique harmonic decay pattern due to carbonization effects. Total Harmonic Distortion (THD) analysis confirms that contamination leads to increased harmonic interference, suggesting its potential as an early indicator of insulation degradation. These findings contribute to the development of predictive maintenance strategies for highvoltage transmission systems, enhancing insulation reliability in extreme environmental conditions.

Authors

Institutions

Publication Details

Published
2025-06-17
DOI
https://doi.org/10.1109/apl65034.2025.11108735
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Frequency-Domain Analysis of Contaminant Effects on Leakage Current and Harmonic Distortion for Transmission Line Diagnostics

Andre Febrian Kasmar, Erhaneli Erhaneli, Sitti Amalia, Zulkarnaini Zulkarnaini et al.
Lightning and Electromagnetic Phenomena
article

Frequency-Domain Analysis of Contaminant Effects on Leakage Current and Harmonic Distortion for Transmission Line Diagnostics

Andre Febrian Kasmar, Erhaneli Erhaneli, Sitti Amalia, Zulkarnaini Zulkarnaini, Yusreni Warmi, Anthonov Anthonov
article en

Abstract

Environmental contaminants such as dust, moss, and flashover residue significantly impact the performance of highvoltage ceramic insulators by altering dielectric properties and increasing leakage current (LC). This study investigates the effect of natural contamination using Fast Fourier Transform (FFT) and harmonic analysis on insulators exposed to realworld conditions in Payakumbuh Koto Panjang. The results indicate that dominant frequencies remain near 50 Hz, with minor shifts (49.95 Hz for moss, 50.06 Hz for dust), highlighting their sensitivity to environmental variations. Magnitude analysis reveals that dust contamination exhibits the highest dominant magnitude (<tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$1.54 \times 10^{-4}$</tex>), indicating stronger energy retention, while harmonic analysis up to the fifth order shows that dust contamination induces the most significant distortions. Flashover residue exhibits a unique harmonic decay pattern due to carbonization effects. Total Harmonic Distortion (THD) analysis confirms that contamination leads to increased harmonic interference, suggesting its potential as an early indicator of insulation degradation. These findings contribute to the development of predictive maintenance strategies for highvoltage transmission systems, enhancing insulation reliability in extreme environmental conditions.

Institut Teknologi Padang (ID)
Openalex Percentile: Top 85%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.