Association of Volume Status Assessed by Bioimpedance with BP in CKD

Key Points Alhough hypervolemia contributes to hypertension, the association of BP with volume status measured by bioimpedance is unclear. Shorter and shortening vector length, proxies of hypervolemia, and volume expansion are associated with higher and increasing systolic BP. Bioimpedance-guided optimization of volume status may improve BP management among patients with CKD. Background Hypertension is common among patients with CKD and is a risk factor for cardiovascular events and mortality. Although hypervolemia is a contributor to hypertension, the association of BP with biomarkers of volume among patients with CKD is unclear. Methods Using data from 5384 patients in the Chronic Renal Insufficiency Cohort, we fit linear regression models to examine the association of vector length (bioimpedance proxy of volume) with systolic and diastolic BP. We used categorical analyses given evidence of nonlinear associations. We also assessed whether the change in vector length at 2 years from baseline was associated with changes in BP. Results The mean age was 59±11 years; 44% were female; 43% were Black; mean systolic BP and eGFR were 129±21 mm Hg and 48±16 ml/min per 1.73 m 2 , respectively. The association of vector length with systolic BP was nonlinear; the lowest quartile of vector length (a proxy for hypervolemia) was associated with a 3.2 mm Hg (95% confidence interval, 1.1 to 5.3) higher systolic BP, compared with the third quartile. Compared with the third quartile over 2 years, the lowest quartile of change in vector length (a proxy for volume expansion) was associated with an increase in systolic BP (3.0 mm Hg; 95% confidence interval, 1.0 to 5.1). Diastolic BP was not associated with vector length. Conclusions Shorter and shortening vector length were independently associated with higher and increasing systolic BP, respectively. Whether bioimpedance-guided optimization of volume status could improve BP management among patients with CKD requires further investigation.

Authors

Institutions

Publication Details

Journal
Kidney360
Published
2025-08-14
DOI
https://doi.org/10.34067/kid.0000000932
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Association of Volume Status Assessed by Bioimpedance with BP in CKD

Brendon Lange Neuen, Finnian R. Mc Causland, Enass Elsayed, Glenn M. Chertow et al.
Kidney360
Hemodynamic Monitoring and Therapy
article

Association of Volume Status Assessed by Bioimpedance with BP in CKD

Brendon Lange Neuen, Finnian R. Mc Causland, Enass Elsayed, Glenn M. Chertow, Katherine Scovner Ravi
article en

Abstract

Key Points Alhough hypervolemia contributes to hypertension, the association of BP with volume status measured by bioimpedance is unclear. Shorter and shortening vector length, proxies of hypervolemia, and volume expansion are associated with higher and increasing systolic BP. Bioimpedance-guided optimization of volume status may improve BP management among patients with CKD. Background Hypertension is common among patients with CKD and is a risk factor for cardiovascular events and mortality. Although hypervolemia is a contributor to hypertension, the association of BP with biomarkers of volume among patients with CKD is unclear. Methods Using data from 5384 patients in the Chronic Renal Insufficiency Cohort, we fit linear regression models to examine the association of vector length (bioimpedance proxy of volume) with systolic and diastolic BP. We used categorical analyses given evidence of nonlinear associations. We also assessed whether the change in vector length at 2 years from baseline was associated with changes in BP. Results The mean age was 59±11 years; 44% were female; 43% were Black; mean systolic BP and eGFR were 129±21 mm Hg and 48±16 ml/min per 1.73 m 2 , respectively. The association of vector length with systolic BP was nonlinear; the lowest quartile of vector length (a proxy for hypervolemia) was associated with a 3.2 mm Hg (95% confidence interval, 1.1 to 5.3) higher systolic BP, compared with the third quartile. Compared with the third quartile over 2 years, the lowest quartile of change in vector length (a proxy for volume expansion) was associated with an increase in systolic BP (3.0 mm Hg; 95% confidence interval, 1.0 to 5.1). Diastolic BP was not associated with vector length. Conclusions Shorter and shortening vector length were independently associated with higher and increasing systolic BP, respectively. Whether bioimpedance-guided optimization of volume status could improve BP management among patients with CKD requires further investigation.

Kidney360Vol. 7(1)
Brigham and Women's Hospital (US), Harvard University (US), UNSW Sydney (AU), The George Institute for Global Health (AU), Stanford University (US)
Openalex Percentile: Top 66%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.