Nitrite testing in excipients – Industry best practices

NNitrosamine risk assessment and control are essential components of pharmaceutical drug development and product evaluation. Nitrites present in excipients pose a risk to vulnerable amines that are present in APIs, API impurities or other process related amines, as they can be nitrosated to form N-nitrosamines. Detection and quantification of nitrite in excipients is an essential undertaking within the pharmaceutical industry to inform nitrosamine risk assessment and related risk mitigation strategies. An industry consortium and Lhasa Nitrites database was established to collaborate on this challenge, share knowledge, and reduce the testing burden. This article demonstrates the existing understanding of analytical techniques within this consortium for the quantification of nitrite in excipients incorporating IC with conductivity or UV detection, Griess derivatisation (with subsequent HPLC-UV or MS/MS detection or as PCD after IC), DAN derivatisation (with FL and MS detection) and cyclamate derivatisation (with GC-FID or GC-MS detection). We aim to highlight a variety of best practices as well as detailing their techniques principles, performance characteristics and sample preparation. Utilising the nitrite results in the database has highlighted a range in LOQs of nitrite that can be achieved, as well as knowledge of the advantages and disadvantages of using each analytical technique. This publication aims to facilitate the selection of an appropriate analytical method when considering nitrite in excipient determination.

Authors

Institutions

Publication Details

Journal
European Journal of Pharmaceutical Sciences
Published
2025-08-12
DOI
https://doi.org/10.1016/j.ejps.2025.107236
Citations
3
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
2.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nitrite testing in excipients – Industry best practices

Grace Kocks, Gemma Packer, Giorgio Blom, Juan M. Pallicer et al.
3 citations
European Journal of Pharmaceutical Sciences
Advanced Chemical Sensor Technologies
2.02
article

Nitrite testing in excipients – Industry best practices

Grace Kocks, Gemma Packer, Giorgio Blom, Juan M. Pallicer, Chris Smith, Tamás Balogh, Jinjian Zheng, Sebastian Hickert, T. van der Wijk, Kevin Näf, James Sabatowski, Emma Pata, Roy Akkermans, Stéphanie Thonne
article en
3 citations

Abstract

NNitrosamine risk assessment and control are essential components of pharmaceutical drug development and product evaluation. Nitrites present in excipients pose a risk to vulnerable amines that are present in APIs, API impurities or other process related amines, as they can be nitrosated to form N-nitrosamines. Detection and quantification of nitrite in excipients is an essential undertaking within the pharmaceutical industry to inform nitrosamine risk assessment and related risk mitigation strategies. An industry consortium and Lhasa Nitrites database was established to collaborate on this challenge, share knowledge, and reduce the testing burden. This article demonstrates the existing understanding of analytical techniques within this consortium for the quantification of nitrite in excipients incorporating IC with conductivity or UV detection, Griess derivatisation (with subsequent HPLC-UV or MS/MS detection or as PCD after IC), DAN derivatisation (with FL and MS detection) and cyclamate derivatisation (with GC-FID or GC-MS detection). We aim to highlight a variety of best practices as well as detailing their techniques principles, performance characteristics and sample preparation. Utilising the nitrite results in the database has highlighted a range in LOQs of nitrite that can be achieved, as well as knowledge of the advantages and disadvantages of using each analytical technique. This publication aims to facilitate the selection of an appropriate analytical method when considering nitrite in excipient determination.

European Journal of Pharmaceutical SciencesVol. 213
AstraZeneca (United Kingdom) (GB), Merck & Co., Inc., Rahway, NJ, USA (United States) (US), University of Hertfordshire (GB), Merck KGaA, Darmstadt (Germany) (DE), Eli Lilly (United States) (US), Pfizer (United Kingdom) (GB), Abbott (United Kingdom) (GB), Ducks Unlimited (US), Idorsia (Switzerland) (CH), Stratophase (United Kingdom) (GB), Bayer (Germany) (DE), UCB Pharma (Belgium) (BE), Actelion (Switzerland) (CH)
Partnerships for the goals
Openalex Percentile: Top 13%
Advanced Chemical Sensor Technologies
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.