A dual-ion-selective electrode system for real-time monitoring of dissolved ammonia

A robust, all-solid-state potentiometric sensor was developed for the selective detection of dissolved ammonia (NH<sub>3</sub>) in aqueous and gas-equilibrated environments. The sensor design is based on a coupled configuration of a nonactin-based ammonium-selective electrode (NH<sub>4</sub><sup>+</sup>-ISE) and a hydrogen ion-selective electrode (H<sup>+</sup>-ISE), enabling direct measurement of NH<sub>3</sub> activity through the equilibrium: NH<sub>4</sub><sup>+</sup> ⇌ NH<sub>3</sub> + H<sup>+</sup>. The resulting electrochemical cell exhibited a near-Nernstian response over a wide dynamic range, with a detection limit below 10 ppm and a response time under 6 seconds. In contrast to conventional membrane-based gas sensors, the dual-electrode system showed minimal signal drift and eliminated the need for gas-permeable membranes or internal filling solutions. Sensor performance was evaluated under various pH and ionic strength conditions, confirming matrix-independent behavior and suitability for direct application in complex environmental samples such as seawater and wastewater. The sensor also demonstrated excellent reversibility and real-time monitoring capability during dynamic NH<sub>3</sub> fluctuation experiments in a freshwater aquaculture system, successfully tracking diurnal changes linked to photosynthetic and respiratory activity. A comparison with a commercial Severinghaus-type ammonia gas probe revealed significantly enhanced stability, faster response, and improved reproducibility for the proposed device. This dual-ion-selective electrode system offers a practical and high-performance platform for on-site NH<sub>3</sub> detection in environmental, aquacultural, and biological monitoring applications.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2025-01-01
DOI
https://doi.org/10.1039/d5an00647c
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A dual-ion-selective electrode system for real-time monitoring of dissolved ammonia

Ayman H. Kamel, Hisham S. M. Abd‐Rabboh
The Analyst
Analytical Chemistry and Sensors
article

A dual-ion-selective electrode system for real-time monitoring of dissolved ammonia

Ayman H. Kamel, Hisham S. M. Abd‐Rabboh
article en

Abstract

A robust, all-solid-state potentiometric sensor was developed for the selective detection of dissolved ammonia (NH<sub>3</sub>) in aqueous and gas-equilibrated environments. The sensor design is based on a coupled configuration of a nonactin-based ammonium-selective electrode (NH<sub>4</sub><sup>+</sup>-ISE) and a hydrogen ion-selective electrode (H<sup>+</sup>-ISE), enabling direct measurement of NH<sub>3</sub> activity through the equilibrium: NH<sub>4</sub><sup>+</sup> ⇌ NH<sub>3</sub> + H<sup>+</sup>. The resulting electrochemical cell exhibited a near-Nernstian response over a wide dynamic range, with a detection limit below 10 ppm and a response time under 6 seconds. In contrast to conventional membrane-based gas sensors, the dual-electrode system showed minimal signal drift and eliminated the need for gas-permeable membranes or internal filling solutions. Sensor performance was evaluated under various pH and ionic strength conditions, confirming matrix-independent behavior and suitability for direct application in complex environmental samples such as seawater and wastewater. The sensor also demonstrated excellent reversibility and real-time monitoring capability during dynamic NH<sub>3</sub> fluctuation experiments in a freshwater aquaculture system, successfully tracking diurnal changes linked to photosynthetic and respiratory activity. A comparison with a commercial Severinghaus-type ammonia gas probe revealed significantly enhanced stability, faster response, and improved reproducibility for the proposed device. This dual-ion-selective electrode system offers a practical and high-performance platform for on-site NH<sub>3</sub> detection in environmental, aquacultural, and biological monitoring applications.

The AnalystVol. 150(18)
University of Bahrain (BH), Ain Shams University (EG), King Khalid University (SA)
King Khalid University
Life below water
Openalex Percentile: Top 73%
Analytical Chemistry and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.