Study on the optimal dry ice dosage for coal seam freezing coring at different coring depths: experiment and modeling

• The temperature variation law of coring tubes at different depths was obtained. • The simulation revealed the temperature and heat variations of the coring tube. • The correlation between optimal freezing dose and coring depth was established. • The simulation confirmed the accuracy of calculating the optimal refrigerant dose. The key to applying freezing coring technology in measuring coal seam gas content lies in accurately estimating the refrigerant dosage. As coring depth increases, the heat generated by the coring tube rises, and accordingly, the required refrigerant dosage changes. To determine the optimal refrigerant dosage for freezing coring at different depths, this study used a self-developed coring simulation device to conduct simulated coring tests at various depths. The temperature variation characteristics of the coring tube at different depths were analyzed, and the heat generated during coring was calculated. Based on these results, the optimal refrigerant dosage was estimated, and a model was proposed for calculating the optimal dosage for freezing coring at different depths. The results show that as coring depth increases, the temperature of the coring tube rises gradually, while the rate of temperature increase slows down. Both the heat generated and dissipated by the coring tube increase with depth; the rate of heat generation slows gradually, while the rate of heat dissipation accelerates. At coring depths of 20 m, 40 m, 60 m, 100 m, and 140 m, the optimal refrigerant dosages were 1.26 kg, 1.52 kg, 1.69 kg, 2.01 kg, and 2.38 kg, respectively. A significant positive linear correlation was observed between refrigerant dosage and coring depth. Validated by numerical simulations, this model was confirmed to effectively estimate the optimal refrigerant dosage for freezing coring at different depths, providing theoretical guidance and references for the development and application of low-temperature freezing coring technology in coal seam gas content measurement.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-08-08
DOI
https://doi.org/10.1016/j.rineng.2025.106677
Citations
2
Primary Topic
Arctic and Antarctic ice dynamics
Type
article
Field-Weighted Citation Impact
2.60

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the optimal dry ice dosage for coal seam freezing coring at different coring depths: experiment and modeling

Shijie Li, Demin Chen, Yang Qiu, Liguo Wang et al.
2 citations
Results in Engineering
Arctic and Antarctic ice dynamics
2.60
article

Study on the optimal dry ice dosage for coal seam freezing coring at different coring depths: experiment and modeling

Shijie Li, Demin Chen, Yang Qiu, Liguo Wang, Shujun Ma, Zhaofeng Wang
article en
2 citations

Abstract

• The temperature variation law of coring tubes at different depths was obtained. • The simulation revealed the temperature and heat variations of the coring tube. • The correlation between optimal freezing dose and coring depth was established. • The simulation confirmed the accuracy of calculating the optimal refrigerant dose. The key to applying freezing coring technology in measuring coal seam gas content lies in accurately estimating the refrigerant dosage. As coring depth increases, the heat generated by the coring tube rises, and accordingly, the required refrigerant dosage changes. To determine the optimal refrigerant dosage for freezing coring at different depths, this study used a self-developed coring simulation device to conduct simulated coring tests at various depths. The temperature variation characteristics of the coring tube at different depths were analyzed, and the heat generated during coring was calculated. Based on these results, the optimal refrigerant dosage was estimated, and a model was proposed for calculating the optimal dosage for freezing coring at different depths. The results show that as coring depth increases, the temperature of the coring tube rises gradually, while the rate of temperature increase slows down. Both the heat generated and dissipated by the coring tube increase with depth; the rate of heat generation slows gradually, while the rate of heat dissipation accelerates. At coring depths of 20 m, 40 m, 60 m, 100 m, and 140 m, the optimal refrigerant dosages were 1.26 kg, 1.52 kg, 1.69 kg, 2.01 kg, and 2.38 kg, respectively. A significant positive linear correlation was observed between refrigerant dosage and coring depth. Validated by numerical simulations, this model was confirmed to effectively estimate the optimal refrigerant dosage for freezing coring at different depths, providing theoretical guidance and references for the development and application of low-temperature freezing coring technology in coal seam gas content measurement.

Results in EngineeringVol. 27
State Administration of Work Safety (CN), Ministry of Civil Affairs (CN), Henan Polytechnic University (CN)
National Natural Science Foundation of China
Life below water
Openalex Percentile: Top 10%
Arctic and Antarctic ice dynamics
2.60
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.