Design and fabrication of smartphone based single paper lateral flow assay for early detection of PCOS biomarker

Polycystic Ovary Syndrome (PCOS) is a multifactorial endocrine disorder with significant diagnostic challenges, especially in early stages. Current diagnostic methods are often complex, time-consuming, and dependent on laboratory-based infrastructure. This study presents the design and fabrication of a smartphone-assisted paper-based lateral flow assay (LFA) for the early detection of PCOS via the quantification of sex hormone-binding globulin (SHBG), a promising metabolic biomarker. Fluorescent nitrogen-doped carbon dots (CDs) were synthesized using a microwave-assisted method and conjugated with anti-SHBG antibodies via EDC/NHS chemistry. The LFA strips were constructed using Whatman filter paper, and hydrophobic barriers were drawn using permanent marker ink. A portable device equipped with a 365 nm UV LED and a smartphone camera enabled fluorescence detection. Recombinant SHBG antigen samples in phosphate-buffered saline (PBS) were tested across a concentration range of 80–4000 ng/mL. The system exhibited a strong linear response (R 2 = 0.9677) between SHBG concentration and fluorescence intensity, with a calculated limit of detection (LOD) and limit of quantification (LOQ) of 2.68 ng/mL and 19.93 ng/mL, respectively. The analytical range of 80–4000 ng/mL corresponds to 0.8–42.1 nmol/L, covers the clinical diagnostic threshold of SHBG (<36 nmol/L). These results demonstrate the feasibility of a low-cost, point-of-care diagnostic tool for early PCOS screening. Further validation with clinical samples is necessary for real-world deployment. • Developed a smartphone-assisted paper-based LFA for early detection of PCOS biomarker SHBG. • Achieved sensitive fluorescence-based detection with an LOQ of 19.15 ng/mL and strong linearity (R 2 = 0.9679). • Demonstrated a low-cost, portable diagnostic platform suitable for point-of-care PCOS screening.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-08-08
DOI
https://doi.org/10.1016/j.biosx.2025.100672
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and fabrication of smartphone based single paper lateral flow assay for early detection of PCOS biomarker

Deepshikha Thakur, Kalicharan Sharma, Sukumar Nandi, Yash Kumar Gaur et al.
1 citations
Biosensors and Bioelectronics X
Biosensors and Analytical Detection
0.67
article

Design and fabrication of smartphone based single paper lateral flow assay for early detection of PCOS biomarker

Deepshikha Thakur, Kalicharan Sharma, Sukumar Nandi, Yash Kumar Gaur, Ekta Daweshar
article en
1 citations

Abstract

Polycystic Ovary Syndrome (PCOS) is a multifactorial endocrine disorder with significant diagnostic challenges, especially in early stages. Current diagnostic methods are often complex, time-consuming, and dependent on laboratory-based infrastructure. This study presents the design and fabrication of a smartphone-assisted paper-based lateral flow assay (LFA) for the early detection of PCOS via the quantification of sex hormone-binding globulin (SHBG), a promising metabolic biomarker. Fluorescent nitrogen-doped carbon dots (CDs) were synthesized using a microwave-assisted method and conjugated with anti-SHBG antibodies via EDC/NHS chemistry. The LFA strips were constructed using Whatman filter paper, and hydrophobic barriers were drawn using permanent marker ink. A portable device equipped with a 365 nm UV LED and a smartphone camera enabled fluorescence detection. Recombinant SHBG antigen samples in phosphate-buffered saline (PBS) were tested across a concentration range of 80–4000 ng/mL. The system exhibited a strong linear response (R 2 = 0.9677) between SHBG concentration and fluorescence intensity, with a calculated limit of detection (LOD) and limit of quantification (LOQ) of 2.68 ng/mL and 19.93 ng/mL, respectively. The analytical range of 80–4000 ng/mL corresponds to 0.8–42.1 nmol/L, covers the clinical diagnostic threshold of SHBG (<36 nmol/L). These results demonstrate the feasibility of a low-cost, point-of-care diagnostic tool for early PCOS screening. Further validation with clinical samples is necessary for real-world deployment. • Developed a smartphone-assisted paper-based LFA for early detection of PCOS biomarker SHBG. • Achieved sensitive fluorescence-based detection with an LOQ of 19.15 ng/mL and strong linearity (R 2 = 0.9679). • Demonstrated a low-cost, portable diagnostic platform suitable for point-of-care PCOS screening.

Biosensors and Bioelectronics XVol. 26
Indo Soviet Friendship College of Pharmacy (IN), National Institute of Pharmaceutical Education and Research - Ahmedabad (IN)
Openalex Percentile: Top 28%
Biosensors and Analytical Detection
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.