Perbandingan Profil Anestesi Kloroform dan Eter Ditinjau dari Waktu Induksi, Durasi, dan Efek Samping pada Tikus Putih

This study aims to comparatively analyze the effects of two types of inhalation anesthetics, ether and chloroform, on Wistar rats, focusing on three main parameters: induction time, duration of anesthesia, and side effects. Selecting the appropriate anesthetic method is crucial in animal studies to ensure animal welfare and the validity of the results. Twenty male Wistar rats, with an average body weight of 200–250 grams and 10–12 weeks of age, were randomly divided into two treatment groups of 10 rats each. The first group was anesthetized using ether, while the second group was anesthetized using chloroform, with doses adjusted to achieve adequate levels of anesthesia. Measurements were made of the induction time, which is the interval from the start of anesthetic exposure until the loss of the pedal reflex; the duration of anesthesia, which is the length of time until the rat regains consciousness; and clinical observations of any side effects that appear, both during and after anesthesia. The results showed that the ether group had a relatively longer induction time than the chloroform group. However, ether provided a longer and more stable duration of anesthesia, with a better recovery rate. In contrast, chloroform produced a shorter induction time but was accompanied by a shorter duration of anesthesia and a higher risk of side effects, particularly liver dysfunction and respiratory depression. These findings reinforce previous reports that chloroform has significant potential toxicity, and its use in animal research should be limited. Based on these results, ether is recommended as a relatively safe inhalation anesthetic option for laboratory procedures in Wistar rats, although its use still requires strict supervision and appropriate handling procedures to ensure the safety of both researchers and experimental animals.

Authors

Institutions

Publication Details

Journal
Inovasi Kesehatan Global
Published
2025-08-08
DOI
https://doi.org/10.62383/ikg.v2i3.2231
Primary Topic
Veterinary Pharmacology and Anesthesia
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Perbandingan Profil Anestesi Kloroform dan Eter Ditinjau dari Waktu Induksi, Durasi, dan Efek Samping pada Tikus Putih

Susan T. Herman, Haryanto Haryanto, Ahmed Mahdi, Zalva Atalya Rieuwpassa et al.
Inovasi Kesehatan Global
Veterinary Pharmacology and Anesthesia
article

Perbandingan Profil Anestesi Kloroform dan Eter Ditinjau dari Waktu Induksi, Durasi, dan Efek Samping pada Tikus Putih

Susan T. Herman, Haryanto Haryanto, Ahmed Mahdi, Zalva Atalya Rieuwpassa, Ashaja Syamsi
article en

Abstract

This study aims to comparatively analyze the effects of two types of inhalation anesthetics, ether and chloroform, on Wistar rats, focusing on three main parameters: induction time, duration of anesthesia, and side effects. Selecting the appropriate anesthetic method is crucial in animal studies to ensure animal welfare and the validity of the results. Twenty male Wistar rats, with an average body weight of 200–250 grams and 10–12 weeks of age, were randomly divided into two treatment groups of 10 rats each. The first group was anesthetized using ether, while the second group was anesthetized using chloroform, with doses adjusted to achieve adequate levels of anesthesia. Measurements were made of the induction time, which is the interval from the start of anesthetic exposure until the loss of the pedal reflex; the duration of anesthesia, which is the length of time until the rat regains consciousness; and clinical observations of any side effects that appear, both during and after anesthesia. The results showed that the ether group had a relatively longer induction time than the chloroform group. However, ether provided a longer and more stable duration of anesthesia, with a better recovery rate. In contrast, chloroform produced a shorter induction time but was accompanied by a shorter duration of anesthesia and a higher risk of side effects, particularly liver dysfunction and respiratory depression. These findings reinforce previous reports that chloroform has significant potential toxicity, and its use in animal research should be limited. Based on these results, ether is recommended as a relatively safe inhalation anesthetic option for laboratory procedures in Wistar rats, although its use still requires strict supervision and appropriate handling procedures to ensure the safety of both researchers and experimental animals.

Inovasi Kesehatan GlobalVol. 2(3)
Muhammadiyah University of Makassar (ID)
Openalex Percentile: Top 78%
Veterinary Pharmacology and Anesthesia
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Perbandingan Profil Anestesi Kloroform dan Eter Ditinjau dari Waktu Induksi, Durasi, dan Efek Samping pada Tikus Putih — Susan T. Herman, Haryanto Haryanto, et al. · Inovasi Kesehatan Global (2025) | TGRS Research Map | TGRS