Determining the Sulfate Content in Phosphogypsum and Cement-Based Materials Based on Conductivity Titration

Accurate determination of sulfate content in phosphogypsum (PG) and cement-based materials is crucial for understanding the corrosion mechanisms of cement-based materials, developing corrosion models, establishing durability design methods, and implementing maintenance strategies. To overcome the limitations of traditional gravimetric and EDTA titration methods in accurately quantifying low-concentration SO<sub>4</sub><sup>2-</sup> in PG and cement-based materials, an IoT-enabled conductometric titration system was developed to improve precision and automation. First, the principle of conductivity titration is introduced, in which Ba(NO<sub>3</sub>)<sub>2</sub> is used as the titrant. Second, a method for eliminating the effects of H<sup>+</sup>, Cl<sup>-</sup>, and Ca<sup>2+</sup> ions is proposed. The impact of the titration rate, volume of liquid to be measured, titrant concentration, and other interfering ions on the results is discussed. Finally, the conductivity titration method was successfully applied to determine sulfate content in PG and cement-based materials. The results demonstrate that the self-developed conductivity titrator exhibits high testing accuracy, with a standard deviation of 0.013 for 15 repeated titrations, a coefficient of variation of 0.52%, and a recovery rate between 103.2% and 103.9%. The optimal solution volume to be determined was 5 mL. Ba(NO<sub>3</sub>)<sub>2</sub>, at approximately twice the sulfate concentration, enhances endpoint sensitivity and minimizes precipitation interference. Ag<sub>2</sub>O and CO<sub>2</sub> significantly reduce the interference from H<sup>+</sup>, Cl<sup>-</sup>, and Ca<sup>2+</sup> ions by generating weakly conductive substances, such as H<sub>2</sub>O, AgCl, Ag<sub>3</sub>PO<sub>4</sub>, CaF<sub>2</sub>, and CaCO<sub>3</sub>. Conductometric titration demonstrated accurate SO<sub>4</sub><sup>2-</sup> quantification in PG and cement-based materials, enabling standardized protocols. This approach provides both theoretical and technical support for rapid sulfate detection in complex systems, with significant implications for both industry and academia. For the industry, it offers a reliable and standardized method for sulfate detection, enhancing quality control and process efficiency. For academia, it establishes a foundation for further research in civil engineering and environmental material analysis, contributing to both practical applications and theoretical advancements.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-08-11
DOI
https://doi.org/10.3390/ma18163758
Primary Topic
Smart Materials for Construction
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining the Sulfate Content in Phosphogypsum and Cement-Based Materials Based on Conductivity Titration

Jun Ren, Zhiyong Liu, Yudong Sun, Xincheng Li et al.
Materials
Smart Materials for Construction
article

Determining the Sulfate Content in Phosphogypsum and Cement-Based Materials Based on Conductivity Titration

Jun Ren, Zhiyong Liu, Yudong Sun, Xincheng Li, Jieming Zhang, Dafu Wang, Jingting Zhou
article en

Abstract

Accurate determination of sulfate content in phosphogypsum (PG) and cement-based materials is crucial for understanding the corrosion mechanisms of cement-based materials, developing corrosion models, establishing durability design methods, and implementing maintenance strategies. To overcome the limitations of traditional gravimetric and EDTA titration methods in accurately quantifying low-concentration SO<sub>4</sub><sup>2-</sup> in PG and cement-based materials, an IoT-enabled conductometric titration system was developed to improve precision and automation. First, the principle of conductivity titration is introduced, in which Ba(NO<sub>3</sub>)<sub>2</sub> is used as the titrant. Second, a method for eliminating the effects of H<sup>+</sup>, Cl<sup>-</sup>, and Ca<sup>2+</sup> ions is proposed. The impact of the titration rate, volume of liquid to be measured, titrant concentration, and other interfering ions on the results is discussed. Finally, the conductivity titration method was successfully applied to determine sulfate content in PG and cement-based materials. The results demonstrate that the self-developed conductivity titrator exhibits high testing accuracy, with a standard deviation of 0.013 for 15 repeated titrations, a coefficient of variation of 0.52%, and a recovery rate between 103.2% and 103.9%. The optimal solution volume to be determined was 5 mL. Ba(NO<sub>3</sub>)<sub>2</sub>, at approximately twice the sulfate concentration, enhances endpoint sensitivity and minimizes precipitation interference. Ag<sub>2</sub>O and CO<sub>2</sub> significantly reduce the interference from H<sup>+</sup>, Cl<sup>-</sup>, and Ca<sup>2+</sup> ions by generating weakly conductive substances, such as H<sub>2</sub>O, AgCl, Ag<sub>3</sub>PO<sub>4</sub>, CaF<sub>2</sub>, and CaCO<sub>3</sub>. Conductometric titration demonstrated accurate SO<sub>4</sub><sup>2-</sup> quantification in PG and cement-based materials, enabling standardized protocols. This approach provides both theoretical and technical support for rapid sulfate detection in complex systems, with significant implications for both industry and academia. For the industry, it offers a reliable and standardized method for sulfate detection, enhancing quality control and process efficiency. For academia, it establishes a foundation for further research in civil engineering and environmental material analysis, contributing to both practical applications and theoretical advancements.

MaterialsVol. 18(16)
Yunnan University (CN), China Academy of Building Research (CN), Southeast University (CN)
National Natural Science Foundation of China, Southeast University, Jiangsu Key Laboratory of Construction Materials
Openalex Percentile: Top 85%
Smart Materials for Construction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.