Influence of the steel tube thickness on the perfobond connectors load capacity

Steel-concrete composite structures is one of the most explosive rapidly developing, cost-effective, and environmentally sustainable processes frequently utilised in high-rise structures and medium-span bridge decks. This research presents an experimental work to investigate the performance of a composite, concrete-filled steel tube (CFST) specimens manufactured by self-compacting concrete (SCC) under a push-out test. Ten CFST specimens have been considered in the experimental tests with a combined two concrete slab. Two variables have been considered in the experimental tests: thickness of tested tube (5 mm and 6 mm) and concrete slab strength (25, 35,45, 55, and 65 MPa). For comparison, all concrete slabs are made with normal concrete and steel tubes filled with SCC. The ultimate shear strength, load-slip behavior, failure load, crack pattern, and failure mode were studied. The experimental results present that the ultimate shear capacity and specimens stiffness improved by increased concrete block strength from 25 to 65 MPa. In addition, it was found, that at the slab concrete strength reduction from about 65 to 25 MPa, it decreased by 4.45%, 9.75%, 14.44%, and 18.34% for 5 mm tube thickness, however, for 6 mm thickness tested specimens, it decreased by 5.36%, 9.35%, 16.04%, and 19.6%, respectively. The specimen with the 6 mm-thick steel tube had better ultimate force capacity and specimens stiffness than the one with the 5 mm-thick tested tube. The perfobond rib is utilised as an effective shear connection in composite or hybrid structures due to its adequate ductility and enhanced shear capacity.

Authors

Institutions

Publication Details

Journal
Roads and Bridges - Drogi i Mosty
Published
2025-08-11
DOI
https://doi.org/10.7409/rabdim.025.016
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of the steel tube thickness on the perfobond connectors load capacity

Khawla Abbas Farhan
4 links
Roads and Bridges - Drogi i Mosty
Structural Load-Bearing Analysis
article

Influence of the steel tube thickness on the perfobond connectors load capacity

Khawla Abbas Farhan
article en

Abstract

Steel-concrete composite structures is one of the most explosive rapidly developing, cost-effective, and environmentally sustainable processes frequently utilised in high-rise structures and medium-span bridge decks. This research presents an experimental work to investigate the performance of a composite, concrete-filled steel tube (CFST) specimens manufactured by self-compacting concrete (SCC) under a push-out test. Ten CFST specimens have been considered in the experimental tests with a combined two concrete slab. Two variables have been considered in the experimental tests: thickness of tested tube (5 mm and 6 mm) and concrete slab strength (25, 35,45, 55, and 65 MPa). For comparison, all concrete slabs are made with normal concrete and steel tubes filled with SCC. The ultimate shear strength, load-slip behavior, failure load, crack pattern, and failure mode were studied. The experimental results present that the ultimate shear capacity and specimens stiffness improved by increased concrete block strength from 25 to 65 MPa. In addition, it was found, that at the slab concrete strength reduction from about 65 to 25 MPa, it decreased by 4.45%, 9.75%, 14.44%, and 18.34% for 5 mm tube thickness, however, for 6 mm thickness tested specimens, it decreased by 5.36%, 9.35%, 16.04%, and 19.6%, respectively. The specimen with the 6 mm-thick steel tube had better ultimate force capacity and specimens stiffness than the one with the 5 mm-thick tested tube. The perfobond rib is utilised as an effective shear connection in composite or hybrid structures due to its adequate ductility and enhanced shear capacity.

Roads and Bridges - Drogi i MostyVol. 24(3)
University of Al-Qadisiyah (IQ)
Openalex Percentile: Top 79%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of the steel tube thickness on the perfobond connectors load capacity — Khawla Abbas Farhan · Roads and Bridges - Drogi i Mosty (2025) | TGRS Research Map | TGRS