Resolution test of STED microscopy using nanodiamonds with embedded nitrogen-vacancy centers

We investigated the suitability of nanodiamonds (NDs) with nitrogen-vacancy (NV) centres as samples for resolution tests in stimulated emission depletion (STED) microscopy. The nanodiamonds were prepared using three different methods including additional proton irradiation to enhance NV centre density. This high-density sample exhibited stronger photoluminescence intensity, greater fluorescence stability, and higher image contrast under STED conditions. All samples showed strong resistance to damage from high STED laser power. Our results highlight the robustness and effectiveness of NDs with NV centres as reliable standards for evaluating STED microscope resolution.

Authors

Institutions

Publication Details

Published
2025-08-08
DOI
https://doi.org/10.1117/12.3062227
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resolution test of STED microscopy using nanodiamonds with embedded nitrogen-vacancy centers

Stefanie Kroker, Bernd Bodermann, P. Olivero, Pietro Aprà et al.
Diamond and Carbon-based Materials Research
article

Resolution test of STED microscopy using nanodiamonds with embedded nitrogen-vacancy centers

Stefanie Kroker, Bernd Bodermann, P. Olivero, Pietro Aprà, Mohammad Nouri
article en

Abstract

We investigated the suitability of nanodiamonds (NDs) with nitrogen-vacancy (NV) centres as samples for resolution tests in stimulated emission depletion (STED) microscopy. The nanodiamonds were prepared using three different methods including additional proton irradiation to enhance NV centre density. This high-density sample exhibited stronger photoluminescence intensity, greater fluorescence stability, and higher image contrast under STED conditions. All samples showed strong resistance to damage from high STED laser power. Our results highlight the robustness and effectiveness of NDs with NV centres as reliable standards for evaluating STED microscope resolution.

Physikalisch-Technische Bundesanstalt (DE), Istituto Nazionale di Fisica Nucleare (IT), University of Turin (IT), Technische Universität Braunschweig (DE)
Openalex Percentile: Top 85%
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.