Heart Rate Variability Monitoring Using a Chord-Based Algorithms in Low-If Cw Radar Systems

This paper presents a method for accurate noncontact heart rate variability (HRV) monitoring using low-IF continuous wave radar under low SNR conditions. The approach integrates a noise-immune motion sensing (NIMS) technique to enhance SNR by segmenting IF signals, extracting phase information, and reconstructing phase evolution for displacement motion. While effective, NIMS faces challenges with small-amplitude cardiac signals due to limitations of traditional phase demodulation. To overcome this, a chord-based phase demodulation method is introduced, offering dc offset immunity and robust noise resistance. Experimental results demonstrate strong agreement with reference ECG, achieving a 6.45 % average error rate, highlighting its effectiveness in challenging conditions.

Authors

Institutions

Publication Details

Published
2025-06-15
DOI
https://doi.org/10.1109/ims40360.2025.11103803
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Heart Rate Variability Monitoring Using a Chord-Based Algorithms in Low-If Cw Radar Systems

Yuan‐Chi Tseng, Chin‐Lung Yang
Non-Invasive Vital Sign Monitoring
article

Heart Rate Variability Monitoring Using a Chord-Based Algorithms in Low-If Cw Radar Systems

Yuan‐Chi Tseng, Chin‐Lung Yang
article en

Abstract

This paper presents a method for accurate noncontact heart rate variability (HRV) monitoring using low-IF continuous wave radar under low SNR conditions. The approach integrates a noise-immune motion sensing (NIMS) technique to enhance SNR by segmenting IF signals, extracting phase information, and reconstructing phase evolution for displacement motion. While effective, NIMS faces challenges with small-amplitude cardiac signals due to limitations of traditional phase demodulation. To overcome this, a chord-based phase demodulation method is introduced, offering dc offset immunity and robust noise resistance. Experimental results demonstrate strong agreement with reference ECG, achieving a 6.45 % average error rate, highlighting its effectiveness in challenging conditions.

National Cheng Kung University (TW)
Affordable and clean energy
Openalex Percentile: Top 81%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.