Resonance Frequency Retuning System for Flexible MRI Coils

Magnetic resonance imaging plays a vital role in advancing medical diagnostic capabilities. Flexible and stretchable RF coils provide better adaptability to patient anatomy and offers the potential for superior MRI image quality. However, these coils are prone to resonance frequency shifts caused by changes in inductance when stretched, compressed, or bent, which can degrade the signal-to-noise ratio and overall image quality. To address this challenge, we present a non-magnetic system capable of detecting and retuning the coil's resonance frequency to the Larmor frequency. The system operates inside the MRI bore at frequencies of up to 600 MHz, with retuning accuracy up to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm 0.04 \text{MHz}$</tex> at 3T. During phantom scans with a stretched coil, our system demonstrated up to a 30% improvement in SNR. This system represents a significant step toward integrating automatic tuning and matching circuits in future MRI applications, ensuring reliable performance across diverse coil configurations, patient anatomies, and field strengths.

Authors

Institutions

Publication Details

Published
2025-06-15
DOI
https://doi.org/10.1109/ims40360.2025.11103854
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resonance Frequency Retuning System for Flexible MRI Coils

Thejas Vishnu Ramesh, Folk W. Narongrit, Joseph V. Rispoli
Advanced MRI Techniques and Applications
article

Resonance Frequency Retuning System for Flexible MRI Coils

Thejas Vishnu Ramesh, Folk W. Narongrit, Joseph V. Rispoli
article en

Abstract

Magnetic resonance imaging plays a vital role in advancing medical diagnostic capabilities. Flexible and stretchable RF coils provide better adaptability to patient anatomy and offers the potential for superior MRI image quality. However, these coils are prone to resonance frequency shifts caused by changes in inductance when stretched, compressed, or bent, which can degrade the signal-to-noise ratio and overall image quality. To address this challenge, we present a non-magnetic system capable of detecting and retuning the coil's resonance frequency to the Larmor frequency. The system operates inside the MRI bore at frequencies of up to 600 MHz, with retuning accuracy up to <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\pm 0.04 \text{MHz}$</tex> at 3T. During phantom scans with a stretched coil, our system demonstrated up to a 30% improvement in SNR. This system represents a significant step toward integrating automatic tuning and matching circuits in future MRI applications, ensuring reliable performance across diverse coil configurations, patient anatomies, and field strengths.

Purdue University West Lafayette (US), Weldon City Schools (US)
IEEE Foundation
Affordable and clean energy
Openalex Percentile: Top 71%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.