Numerical Testbench for A Priori Uncertainty Estimation of Dielectric Spectroscopy in Organ-On-Chip Devices

In this work, we present a numerical testbench, realized in a circuit simulation environment, enabling a priori uncertainty evaluation of dielectric spectroscopy in the application field of organs-on-chip. This testbench evaluates the impact of noise, ambient temperature variation and impurity of liquid standards on the uncertainty of dielectric spectroscopy measurements. Moreover, the proposed approach allows to account for the impact on measurement sensitivity of system parameters such as probe dimensions and probe coatings. The estimated uncertainty contributions for the considered effects are compared and benchmarked experimentally. Finally, the testbench is employed to project the dielectric spectroscopy accuracy on a relevant biological application, namely monitoring the growth of a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$7 \boldsymbol{\mu}$</tex> m-thick kidney cell monolayer.

Authors

Institutions

Publication Details

Published
2025-06-15
DOI
https://doi.org/10.1109/ims40360.2025.11103818
Citations
1
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Testbench for A Priori Uncertainty Estimation of Dielectric Spectroscopy in Organ-On-Chip Devices

Tim Hosman, Marco Spirito, Massimo Mastrangeli, Ehsan Shokrolahzade
1 citations
Wireless Body Area Networks
0.67
article

Numerical Testbench for A Priori Uncertainty Estimation of Dielectric Spectroscopy in Organ-On-Chip Devices

Tim Hosman, Marco Spirito, Massimo Mastrangeli, Ehsan Shokrolahzade
article en
1 citations

Abstract

In this work, we present a numerical testbench, realized in a circuit simulation environment, enabling a priori uncertainty evaluation of dielectric spectroscopy in the application field of organs-on-chip. This testbench evaluates the impact of noise, ambient temperature variation and impurity of liquid standards on the uncertainty of dielectric spectroscopy measurements. Moreover, the proposed approach allows to account for the impact on measurement sensitivity of system parameters such as probe dimensions and probe coatings. The estimated uncertainty contributions for the considered effects are compared and benchmarked experimentally. Finally, the testbench is employed to project the dielectric spectroscopy accuracy on a relevant biological application, namely monitoring the growth of a <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$7 \boldsymbol{\mu}$</tex> m-thick kidney cell monolayer.

Delft University of Technology (NL)
Affordable and clean energy
Openalex Percentile: Top 28%
Wireless Body Area Networks
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.