A comparison of the four most commonly used formulae to adjust the QT-interval for heart rate in 22,000 healthy subjects
In apparently healthy individuals, Fridericia formula is the most reliable method for correcting the QT interval for heart rate and we recommend its use in studies involving healthy subjects.
Authors
- Leendert J. Hoek
- Alexander H. Maass
- Adriaan A. Voors
- Jan Leendert P. Brouwer
- Martijn Riesebos
Institutions
- University Medical Center Groningen (NL)
- University of Groningen (NL)
- Interuniversity Center for Social Science Theory and Methodology (NL)
Publication Details
- Journal
- Journal of Electrocardiology
- Published
- 2025-08-08
- DOI
- https://doi.org/10.1016/j.jelectrocard.2025.154091
- Citations
- 3
- Primary Topic
- Cardiac electrophysiology and arrhythmias
- Type
- article
- Field-Weighted Citation Impact
- 4.16