Displacement Sensing Based on Parasitic Cavity Referencing in Optical Circulators

In this letter, we propose a method for utilizing the internal cavities of optical circulator devices—commonly referred to as parasitic cavities—as optical reference cavities. The method involves using an optical circulator operating at 1550 nm, illuminated by a light source at 1330 nm, thereby enhancing the amplitude of the interferometric signals generated by the internal optical cavities. The system was characterized by using both an Optical Spectrum Analyzer (OSA) and the Low-Coherence Interferometry (LCI) technique. Experimental results indicate that the Optical Path Difference (OPD) remains constant with varying aperture sizes, thereby confirming the feasibility of employing the optical circulator as a reference sensor. Finally, its performance as a reference sensor is demonstrated through its integration with an external cavity that functions as a displacement sensor.

Authors

Institutions

Publication Details

Journal
IEEE Photonics Technology Letters
Published
2025-08-08
DOI
https://doi.org/10.1109/lpt.2025.3597250
Primary Topic
Magneto-Optical Properties and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Displacement Sensing Based on Parasitic Cavity Referencing in Optical Circulators

A. B. Lobo Ribeiro, Orlando Frazão, Paulo Robalinho, António Vaz et al.
IEEE Photonics Technology Letters
Magneto-Optical Properties and Applications
article

Displacement Sensing Based on Parasitic Cavity Referencing in Optical Circulators

A. B. Lobo Ribeiro, Orlando Frazão, Paulo Robalinho, António Vaz, Susana Silva, Vinicius Paia
article en

Abstract

In this letter, we propose a method for utilizing the internal cavities of optical circulator devices—commonly referred to as parasitic cavities—as optical reference cavities. The method involves using an optical circulator operating at 1550 nm, illuminated by a light source at 1330 nm, thereby enhancing the amplitude of the interferometric signals generated by the internal optical cavities. The system was characterized by using both an Optical Spectrum Analyzer (OSA) and the Low-Coherence Interferometry (LCI) technique. Experimental results indicate that the Optical Path Difference (OPD) remains constant with varying aperture sizes, thereby confirming the feasibility of employing the optical circulator as a reference sensor. Finally, its performance as a reference sensor is demonstrated through its integration with an external cavity that functions as a displacement sensor.

IEEE Photonics Technology LettersVol. 37(22)
Fernando Pessoa University (PT), Universidade do Porto (PT), INESC TEC (PT)
Openalex Percentile: Top 81%
Magneto-Optical Properties and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.