Angular Acceleration-Free IMU-Joint Vector Calibration Based on Measurement Integrals

Inertial sensor-based human motion tracking technology has many applications, including but not limited to sports, cinematic rehabilitation, and gaming. Human pose estimation is highly sensitive to the accuracy of the IMU-joint vector, which is defined from the center of rotation (COR) of joints to the inertial measurement units (IMUs). The sensor measurement error, caused by soft tissue artifacts (STAs), and the joint motion substantially impact the IMU-joint calibration. This article proposes an IMU-joint calibration method based on measurement integrals that does not need the derivative of noisy IMU measurements for angular acceleration. A number of influencing factors such as the STAs noise, IMU-joint distance, and the joint angular velocity are investigated by simulations and real tests. The proposed method demonstrates not only better calibration accuracy but higher robustness than the state-of-the-art methods.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3596998
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Angular Acceleration-Free IMU-Joint Vector Calibration Based on Measurement Integrals

Huahua Yi, Maoran Zhu, Yuanxin Wu, Wangyang Zhao
IEEE Transactions on Instrumentation and Measurement
Advanced Measurement and Detection Methods
article

Angular Acceleration-Free IMU-Joint Vector Calibration Based on Measurement Integrals

Huahua Yi, Maoran Zhu, Yuanxin Wu, Wangyang Zhao
article en

Abstract

Inertial sensor-based human motion tracking technology has many applications, including but not limited to sports, cinematic rehabilitation, and gaming. Human pose estimation is highly sensitive to the accuracy of the IMU-joint vector, which is defined from the center of rotation (COR) of joints to the inertial measurement units (IMUs). The sensor measurement error, caused by soft tissue artifacts (STAs), and the joint motion substantially impact the IMU-joint calibration. This article proposes an IMU-joint calibration method based on measurement integrals that does not need the derivative of noisy IMU measurements for angular acceleration. A number of influencing factors such as the STAs noise, IMU-joint distance, and the joint angular velocity are investigated by simulations and real tests. The proposed method demonstrates not only better calibration accuracy but higher robustness than the state-of-the-art methods.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Shanghai Jiao Tong University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 81%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Angular Acceleration-Free IMU-Joint Vector Calibration Based on Measurement Integrals — Huahua Yi, Maoran Zhu, et al. · IEEE Transactions on Instrumentation and Measurement (2025) | TGRS Research Map | TGRS