The calibration of the four-port three-component probe, measuring <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${H}_{x}$ </tex-math></inline-formula>, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${H}_{y}$ </tex-math></inline-formula>, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${E}_{z}$ </tex-math></inline-formula>, is interesting for near-field measurement. At high frequency, calibration errors caused by the frequency response are very distressing. These error reasons include the multiple refection caused by embedded part of the calibrator (first error term) and the single reflection caused by the probe approaching the calibrator (second error term). The first error term has been proven to be eliminated through de-embedding calibration method of two-port probe. However, the second error term cannot be removed by this method, which will cause the impedance discontinuity of calibration process. In this article, a middle underfill L-standard as a calibrator is proposed for a four-port three-component probe de-embedding calibration. The new L-standard design can increase the inductive reactance of transmission structure to resist the capacitive effect of the probe when approaching the calibrator. The results of simulation or measurement show that the new L-standard can improve the impedance continuity by nearly 75.6% with a suitable height. Compared with traditional embedding calibration method of four-port three-component probe, the frequency response after using the new calibrator can improve about <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.7\sim 2.2$ </tex-math></inline-formula> dB, and the ripples caused by embedded part can be eliminated.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-08
DOI
https://doi.org/10.1109/jsen.2025.3594824
Citations
1
Primary Topic
Microwave and Dielectric Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Middle Underfill L-Standard Design for Highly Impedance Continuity in Four-Port Probe De-Embedding Calibration

Shan Xue, Xinxin Tian, Hui Li, Weiheng Shao et al.
1 citations
IEEE Sensors Journal
Microwave and Dielectric Measurement Techniques
0.73
article

A Middle Underfill L-Standard Design for Highly Impedance Continuity in Four-Port Probe De-Embedding Calibration

Shan Xue, Xinxin Tian, Hui Li, Weiheng Shao, Zhizhe Wang, Litao Ruan, Guoguang Lu, Jun Luo, Zhanjun Huang
article en
1 citations

Abstract

The calibration of the four-port three-component probe, measuring <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${H}_{x}$ </tex-math></inline-formula>, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${H}_{y}$ </tex-math></inline-formula>, and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">${E}_{z}$ </tex-math></inline-formula>, is interesting for near-field measurement. At high frequency, calibration errors caused by the frequency response are very distressing. These error reasons include the multiple refection caused by embedded part of the calibrator (first error term) and the single reflection caused by the probe approaching the calibrator (second error term). The first error term has been proven to be eliminated through de-embedding calibration method of two-port probe. However, the second error term cannot be removed by this method, which will cause the impedance discontinuity of calibration process. In this article, a middle underfill L-standard as a calibrator is proposed for a four-port three-component probe de-embedding calibration. The new L-standard design can increase the inductive reactance of transmission structure to resist the capacitive effect of the probe when approaching the calibrator. The results of simulation or measurement show that the new L-standard can improve the impedance continuity by nearly 75.6% with a suitable height. Compared with traditional embedding calibration method of four-port three-component probe, the frequency response after using the new calibrator can improve about <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$0.7\sim 2.2$ </tex-math></inline-formula> dB, and the ripples caused by embedded part can be eliminated.

IEEE Sensors JournalVol. 25(18)
Northwestern Polytechnical University (CN), China Electronic Product Reliability and Environmental Test Institute (CN)
Natural Science Foundation of Guangdong Province
Affordable and clean energy
Openalex Percentile: Top 25%
Microwave and Dielectric Measurement Techniques
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.