Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset

In power systems increasingly dominated by renewable energy generations, cascaded H-bridge (CHB) multilevel inverters are well-suited for high-power applications. However, CHB topologies are prone to unbalanced conditions due to submodule faults. While redundant submodules are commonly employed to mitigate these issues, they lower efficiency and increase the costs and complexity of circuits. This article addresses unbalanced grid currents caused by faulty submodules in CHB inverters through a neutral point-shifting control strategy. When submodules are bypassed due to faults, all remaining submodules, across both normal and faulty phases, share the lost voltage of the bypassed submodules. The corresponding control strategy is presented in this article, constraints and source voltage stress reduction are analyzed, and the effectiveness is verified by simulation and experimental tests. The proposed method can reduce system costs and downtime, thus enhancing the resilient operation of the entire system.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industrial Electronics
Published
2025-08-08
DOI
https://doi.org/10.1109/tie.2025.3589466
Citations
1
Primary Topic
Power Systems and Renewable Energy
Type
article
Field-Weighted Citation Impact
0.53
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset

Jinli Zhu, Brad Lehman, Yuan Li, Fang Zheng Peng
1 citations
IEEE Transactions on Industrial Electronics
Power Systems and Renewable Energy
0.53
article

Resilient Operation for Grid-Connected Cascaded H-Bridge Multilevel Inverter Based on Neutral Offset

Jinli Zhu, Brad Lehman, Yuan Li, Fang Zheng Peng
article en
1 citations

Abstract

In power systems increasingly dominated by renewable energy generations, cascaded H-bridge (CHB) multilevel inverters are well-suited for high-power applications. However, CHB topologies are prone to unbalanced conditions due to submodule faults. While redundant submodules are commonly employed to mitigate these issues, they lower efficiency and increase the costs and complexity of circuits. This article addresses unbalanced grid currents caused by faulty submodules in CHB inverters through a neutral point-shifting control strategy. When submodules are bypassed due to faults, all remaining submodules, across both normal and faulty phases, share the lost voltage of the bypassed submodules. The corresponding control strategy is presented in this article, constraints and source voltage stress reduction are analyzed, and the effectiveness is verified by simulation and experimental tests. The proposed method can reduce system costs and downtime, thus enhancing the resilient operation of the entire system.

IEEE Transactions on Industrial ElectronicsVol. 72(12)
Northeastern University (US), University of Pittsburgh (US)
Affordable and clean energy
Openalex Percentile: Top 28%
Power Systems and Renewable Energy
0.53
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.