Understanding the Relationship Between Insulation Aging and Gassing Tendency of Some Biodegradable Dielectric Fluids

This study investigates the degradation mechanisms and gas generation behaviors of three biodegradable dielectric fluids, bio-based mineral oils (Bio-MO), natural esters (NE), and synthetic esters (SE), under electrical stress, focusing on their application in power transformers. The research adopts an extended experimental protocol that includes multiple aging durations (250–2000 hours) and repeated breakdown voltage (BDV) tests to simulate arc fault conditions and ensure reproducible trend analysis. Key characterizations such as Dissipation Factor (DDF), Interfacial Tension (IFT), and Total Acid Number (TAN) were combined with Dissolved Gas Analysis (DGA) to monitor fluid degradation. A novel contribution of this work is the statistical correlation framework introduced to quantify the relationships between increases in gases (%C<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>H<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, %TDCG) and aging markers using correlation coefficients (r, p-value). Furthermore, Duval’s diagnostic tools (Triangle 1/Pentagon 1 for Bio-MO, Triangle 3/Pentagon 3 for esters) revealed that fault types evolve with aging. Specifically, Bio-MO transitioned from high-energy (D2) to low-energy (D1) discharges, strongly correlated with rising %DDF and %TAN. In contrast, NE and SE maintained stable D1 diagnostics. These findings offer a predictive approach to fault identification and transformer health assessment, paving the way for broader implementation with larger sample sets and field validation.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Dielectrics and Electrical Insulation
Published
2025-08-08
DOI
https://doi.org/10.1109/tdei.2025.3596945
Primary Topic
Structural Analysis of Composite Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Understanding the Relationship Between Insulation Aging and Gassing Tendency of Some Biodegradable Dielectric Fluids

I. Fofana, U. Mohan Rao, Yazid Hadjadj, Moïse T. Agouassi
IEEE Transactions on Dielectrics and Electrical Insulation
Structural Analysis of Composite Materials
article

Understanding the Relationship Between Insulation Aging and Gassing Tendency of Some Biodegradable Dielectric Fluids

I. Fofana, U. Mohan Rao, Yazid Hadjadj, Moïse T. Agouassi
article en

Abstract

This study investigates the degradation mechanisms and gas generation behaviors of three biodegradable dielectric fluids, bio-based mineral oils (Bio-MO), natural esters (NE), and synthetic esters (SE), under electrical stress, focusing on their application in power transformers. The research adopts an extended experimental protocol that includes multiple aging durations (250–2000 hours) and repeated breakdown voltage (BDV) tests to simulate arc fault conditions and ensure reproducible trend analysis. Key characterizations such as Dissipation Factor (DDF), Interfacial Tension (IFT), and Total Acid Number (TAN) were combined with Dissolved Gas Analysis (DGA) to monitor fluid degradation. A novel contribution of this work is the statistical correlation framework introduced to quantify the relationships between increases in gases (%C<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>H<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, %TDCG) and aging markers using correlation coefficients (r, p-value). Furthermore, Duval’s diagnostic tools (Triangle 1/Pentagon 1 for Bio-MO, Triangle 3/Pentagon 3 for esters) revealed that fault types evolve with aging. Specifically, Bio-MO transitioned from high-energy (D2) to low-energy (D1) discharges, strongly correlated with rising %DDF and %TAN. In contrast, NE and SE maintained stable D1 diagnostics. These findings offer a predictive approach to fault identification and transformer health assessment, paving the way for broader implementation with larger sample sets and field validation.

IEEE Transactions on Dielectrics and Electrical InsulationVol. 33(1)
Université du Québec à Chicoutimi (CA), General Electric (United States) (US), National Research Council Canada (CA)
Openalex Percentile: Top 80%
Structural Analysis of Composite Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.