A self-powered photovoltaic colorimetric detector for sensing metal ions at ultralow concentrations

The accumulation of toxic metal ions from industrial activities poses significant environmental and health risks, thus necessitating the development of portable, rapid, and highly sensitive detection systems. We report a self-powered photovoltaic colorimetric sensor that is capable of detecting Al 3+ , Fe 3+ , and Cu 2+ ions at nanomolar concentrations. Traditional spectrometer-based platforms are bulky and unsuitable for onsite applications, whereas conventional colorimetric sensors often suffer from limited sensitivity and poor reproducibility. To address these limitations, we utilize a rhodamine derivative (R6GH) that undergoes a ring-opening reaction upon interaction with target metal ions, which results in a visible color change under green LED illumination. The portable sensor integrates a Schottky junction that is fabricated by depositing gallium-doped zinc oxide (GZO) onto an n-type silicon substrate via atomic layer deposition, which enables the efficient conversion of optical signals into electrical outputs. The device operates in dual detection mode. In voltage mode, the detection limits are 16 nM for Al 3+ , 22 nM for Fe 3+ , and 41 nM for Cu 2+ . In current mode, the respective detection limits are 26, 18, and 34 nM. Compared with conventional chemosensors, this system offers an improvement in sensitivity of up to two orders of magnitude. Additionally, the sensor demonstrates excellent signal reproducibility, with a relative standard deviation (RSD) of less than 1.14 % across 560 switching cycles. The combination of high sensitivity, rapid response (<30 s), and stable, self-powered operation makes this device a promising candidate for real-time metal ion monitoring for the future of bioelectronic devices in healthcare. • A self-powered photovoltaic colorimetric sensor that is aligned with power-saving goals is developed. • Determination of Al 3+ , Fe 3+ , and Cu 2+ ions at nanomolar concentrations is achieved. • The portable sensor demonstrates a Schottky junction via atomic layer deposition. • The sensor exhibits high sensitivity, a rapid response (<30 s), and stable operation.

Authors

Institutions

Publication Details

Journal
Biosensors and Bioelectronics X
Published
2025-08-08
DOI
https://doi.org/10.1016/j.biosx.2025.100674
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A self-powered photovoltaic colorimetric detector for sensing metal ions at ultralow concentrations

Wei Wu, G. Y. Hou, Chia-Yu Hsu, Yu‐Sheng Lai et al.
Biosensors and Bioelectronics X
Gas Sensing Nanomaterials and Sensors
article

A self-powered photovoltaic colorimetric detector for sensing metal ions at ultralow concentrations

Wei Wu, G. Y. Hou, Chia-Yu Hsu, Yu‐Sheng Lai, Fu‐Hsiang Ko, Yu-Ting Tai, Po-Hsien Tseng, Shang-Yu Tsai
article en

Abstract

The accumulation of toxic metal ions from industrial activities poses significant environmental and health risks, thus necessitating the development of portable, rapid, and highly sensitive detection systems. We report a self-powered photovoltaic colorimetric sensor that is capable of detecting Al 3+ , Fe 3+ , and Cu 2+ ions at nanomolar concentrations. Traditional spectrometer-based platforms are bulky and unsuitable for onsite applications, whereas conventional colorimetric sensors often suffer from limited sensitivity and poor reproducibility. To address these limitations, we utilize a rhodamine derivative (R6GH) that undergoes a ring-opening reaction upon interaction with target metal ions, which results in a visible color change under green LED illumination. The portable sensor integrates a Schottky junction that is fabricated by depositing gallium-doped zinc oxide (GZO) onto an n-type silicon substrate via atomic layer deposition, which enables the efficient conversion of optical signals into electrical outputs. The device operates in dual detection mode. In voltage mode, the detection limits are 16 nM for Al 3+ , 22 nM for Fe 3+ , and 41 nM for Cu 2+ . In current mode, the respective detection limits are 26, 18, and 34 nM. Compared with conventional chemosensors, this system offers an improvement in sensitivity of up to two orders of magnitude. Additionally, the sensor demonstrates excellent signal reproducibility, with a relative standard deviation (RSD) of less than 1.14 % across 560 switching cycles. The combination of high sensitivity, rapid response (<30 s), and stable, self-powered operation makes this device a promising candidate for real-time metal ion monitoring for the future of bioelectronic devices in healthcare. • A self-powered photovoltaic colorimetric sensor that is aligned with power-saving goals is developed. • Determination of Al 3+ , Fe 3+ , and Cu 2+ ions at nanomolar concentrations is achieved. • The portable sensor demonstrates a Schottky junction via atomic layer deposition. • The sensor exhibits high sensitivity, a rapid response (<30 s), and stable operation.

Biosensors and Bioelectronics XVol. 26
National Yang Ming Chiao Tung University (TW), Powertech Technology (Taiwan) (TW), Taiwan Semiconductor Manufacturing Company (Taiwan) (TW)
Affordable and clean energy
Openalex Percentile: Top 82%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.