Mercury‐Free Determination of Lead in Water by Cloud Point Extraction and Anodic Stripping Voltammetry

The toxicity of metal ions, such as lead (Pb 2+ ) and cadmium (Cd 2+ ), has been a worldwide issue since the 1970s. For Pb 2+ specifically, chronic exposure via drinking water can have lasting health effects. While inductively coupled plasma‐mass spectrometry (ICP‐MS) and atomic absorption spectroscopy (AAS) are the most common instruments used for the detection of Pb 2+ , electrochemical methods like square wave anodic stripping voltammetry (SWASV) have classically shown promise. However, the determination of metals in a real sample matrix typically requires pretreatment and/or extraction of the analyte from the sample itself. Cloud point extraction (CPE) is a sustainable technique that can be used as a solventless substitute for liquid–liquid or solid‐phase extraction. While typically coupled to AAS detection, the applicability of CPE to electroanalysis is still not well understood, nor fully optimized. In this work, CPE was used to isolate Pb 2+ from water samples for analysis by SWASV with a bismuth‐coated glassy carbon (Bi‐GC) electrode. This is the first report coupling CPE to electroanalytical detection of trace metals in the absence of mercury (Hg). In addition, a back extraction (BE) step was incorporated to recover Pb 2+ from the surfactant‐rich phase, which resulted in a more sensitive and accurate method. High extraction efficiency was achieved and theoretical limits of detection (LOD) of 2.6, 0.81, and 1.7 μgL −1 were obtained with deposition times ( t dep ) of 1, 2, and 3 min, respectively. The optimized CPE‐SWASV procedure for Pb 2+ was selective; only manganese (Mn 2+ ) was identified as an interferant. Measurements in more complex water samples were also completed. Overall, this innovative CPE‐SWASV approach offers a sensitive, cost‐effective, and sustainable alternative to Hg‐based electrochemical quantification of Pb 2+ .

Authors

Institutions

Publication Details

Journal
Electroanalysis
Published
2025-08-01
DOI
https://doi.org/10.1002/elan.70013
Primary Topic
Electrochemical Analysis and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mercury‐Free Determination of Lead in Water by Cloud Point Extraction and Anodic Stripping Voltammetry

Cory A. Rusinek, Karen A. Gonzalez, Vivian M. Flaum, Dustyn C. Weber
Electroanalysis
Electrochemical Analysis and Applications
article

Mercury‐Free Determination of Lead in Water by Cloud Point Extraction and Anodic Stripping Voltammetry

Cory A. Rusinek, Karen A. Gonzalez, Vivian M. Flaum, Dustyn C. Weber
article en

Abstract

The toxicity of metal ions, such as lead (Pb 2+ ) and cadmium (Cd 2+ ), has been a worldwide issue since the 1970s. For Pb 2+ specifically, chronic exposure via drinking water can have lasting health effects. While inductively coupled plasma‐mass spectrometry (ICP‐MS) and atomic absorption spectroscopy (AAS) are the most common instruments used for the detection of Pb 2+ , electrochemical methods like square wave anodic stripping voltammetry (SWASV) have classically shown promise. However, the determination of metals in a real sample matrix typically requires pretreatment and/or extraction of the analyte from the sample itself. Cloud point extraction (CPE) is a sustainable technique that can be used as a solventless substitute for liquid–liquid or solid‐phase extraction. While typically coupled to AAS detection, the applicability of CPE to electroanalysis is still not well understood, nor fully optimized. In this work, CPE was used to isolate Pb 2+ from water samples for analysis by SWASV with a bismuth‐coated glassy carbon (Bi‐GC) electrode. This is the first report coupling CPE to electroanalytical detection of trace metals in the absence of mercury (Hg). In addition, a back extraction (BE) step was incorporated to recover Pb 2+ from the surfactant‐rich phase, which resulted in a more sensitive and accurate method. High extraction efficiency was achieved and theoretical limits of detection (LOD) of 2.6, 0.81, and 1.7 μgL −1 were obtained with deposition times ( t dep ) of 1, 2, and 3 min, respectively. The optimized CPE‐SWASV procedure for Pb 2+ was selective; only manganese (Mn 2+ ) was identified as an interferant. Measurements in more complex water samples were also completed. Overall, this innovative CPE‐SWASV approach offers a sensitive, cost‐effective, and sustainable alternative to Hg‐based electrochemical quantification of Pb 2+ .

ElectroanalysisVol. 37(8)
University of Nevada, Las Vegas (US), Miami University (US)
University of Miami
Openalex Percentile: Top 77%
Electrochemical Analysis and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.