Nitrite quantification in processed meat using an enzyme biosensor, a portable reader and a smartphone: a facile and accurate approach

The control of nitrite levels in foodstuff is essential for ensuring human safety. However, the protocols are long and require lab equipment (spectrophotometer and centrifuge) not available in industrial or commercial settings. Herein, we adapted an electrochemical nitrite biosensor utilizing the enzyme cytochrome c nitrite reductase (ccNiR) previously developed in our lab, to meet the analytical requirements of cured meats, and validated it using real samples from different brands. The enzyme was immobilized on a disposable carbon screen-printed electrode (SPE) modified with multi-walled carbon nanotubes (MWCNTs) and connected to a hand-held potentiostat coupled to a smartphone. The carbon nanotubes suspension was optimized using chemically friendly solvents and the SPE surface was electrochemically characterized using ferricyanide as a redox probe, to fine-tune the modification formulation. The nitrite biosensor delivered a sensitivity of 0.0103 μA/μM, a linear range from 5 to 100 μM, and a lower detection limit (LOD) of 3.2 μM. Subsequently, the biosensor was tested for its ability to detect nitrites in various processed meat samples, considering factors such as type and origin. The validation of the electrochemical biosensor was conducted using the gold standard Griess method and HPLC, although the first one failed to detect nitrites in some samples due to matrix interferences. Accordingly, the nitrite biosensor performed well, providing highly accurate and precise results (smaller SD), even in non-centrifuged samples, making it possible to control the meat quality at any point of the chain distribution. • A portable enzymatic sensor for nitrite detection was tested and validated in cured meat. • Samples preparation is quick and simple, obviating pre-centrifugation steps. • The biosensors performance showed good agreement with reference methods, presenting matrix interference-free results.

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2025-08-08
DOI
https://doi.org/10.1016/j.microc.2025.114841
Citations
1
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.73

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nitrite quantification in processed meat using an enzyme biosensor, a portable reader and a smartphone: a facile and accurate approach

Franco Mazzei, M. Gabriela Almeida, Rosaceleste Zumpano, Francesca Polli et al.
1 citations
Microchemical Journal
Electrochemical sensors and biosensors
0.73
article

Nitrite quantification in processed meat using an enzyme biosensor, a portable reader and a smartphone: a facile and accurate approach

Franco Mazzei, M. Gabriela Almeida, Rosaceleste Zumpano, Francesca Polli, Július Gajdár, Luca Surace
article en
1 citations

Abstract

The control of nitrite levels in foodstuff is essential for ensuring human safety. However, the protocols are long and require lab equipment (spectrophotometer and centrifuge) not available in industrial or commercial settings. Herein, we adapted an electrochemical nitrite biosensor utilizing the enzyme cytochrome c nitrite reductase (ccNiR) previously developed in our lab, to meet the analytical requirements of cured meats, and validated it using real samples from different brands. The enzyme was immobilized on a disposable carbon screen-printed electrode (SPE) modified with multi-walled carbon nanotubes (MWCNTs) and connected to a hand-held potentiostat coupled to a smartphone. The carbon nanotubes suspension was optimized using chemically friendly solvents and the SPE surface was electrochemically characterized using ferricyanide as a redox probe, to fine-tune the modification formulation. The nitrite biosensor delivered a sensitivity of 0.0103 μA/μM, a linear range from 5 to 100 μM, and a lower detection limit (LOD) of 3.2 μM. Subsequently, the biosensor was tested for its ability to detect nitrites in various processed meat samples, considering factors such as type and origin. The validation of the electrochemical biosensor was conducted using the gold standard Griess method and HPLC, although the first one failed to detect nitrites in some samples due to matrix interferences. Accordingly, the nitrite biosensor performed well, providing highly accurate and precise results (smaller SD), even in non-centrifuged samples, making it possible to control the meat quality at any point of the chain distribution. • A portable enzymatic sensor for nitrite detection was tested and validated in cured meat. • Samples preparation is quick and simple, obviating pre-centrifugation steps. • The biosensors performance showed good agreement with reference methods, presenting matrix interference-free results.

Microchemical JournalVol. 217
Escola Superior de Saúde Egas Moniz (PT), Universidade Nova de Lisboa (PT), Sapienza University of Rome (IT)
Applied Molecular Biosciences Unit, Fundação para a Ciência e a Tecnologia
Zero hunger
Openalex Percentile: Top 25%
Electrochemical sensors and biosensors
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.