Resolving Nanoscale Phases Purity and Lattice Strain in Multi‐Cationic Perovskite Solar Cells for Enhanced Stability
A-site cations in organic-inorganic lead halide perovskites (OLHPs) critically stabilize phases, inhibit ion migration, and reinforce interfaces, ensuring device operational stability. However, the mechanistic links between A-cation engineering and phase purity, and lattice strain in determining perovskite solar cell stability remain elusive. Here, optimized hybrid perovskite A-site cation ratios (FA:70-90%, MA:5-15%, Cs:5-25%) are achieved using an orthogonal L<sub>9</sub> (3^<sup>4</sup>) array, reducing experimental permutations by 66.7% while maintaining statistical rigor through balanced phase-space sampling and orthogonal factor matching, revealing composition-dependent linkages among phase purity, lattice strain, and stability in OLHPs. The results demonstrate that cation coordination hierarchy (FA<sup>+</sup>>MA<sup>+</sup>>Cs<sup>+</sup>>Rb<sup>+</sup>) governing phases purity. Further, Rb<sup>+</sup> substitution markedly suppresses defect density in quaternary FA<sub>0.82</sub>MA<sub>0.05</sub>Cs<sub>0.05</sub>Rb<sub>0.08</sub>PbI<sub>3</sub> films. The geometric phase analysis (GPA) demonstrates that stark contrasts between ternary (FA<sub>0.80</sub>MA<sub>0.15</sub>Cs<sub>0.05</sub>PbI<sub>3</sub>) and quaternary (FA<sub>0.82</sub>MA<sub>0.05</sub>Cs<sub>0.05</sub>Rb<sub>0.08</sub>PbI<sub>3</sub>) perovskites: the former exhibits pronounced compressive (ɛ<sub>xx</sub> = -3.3%) and tensile (ɛ<sub>yy</sub> = 27.5%) strains, whereas the latter shows significantly reduced strain magnitudes (ɛ<sub>xx</sub> = -1.2%, ɛ<sub>yy</sub> = 1.6%), indicative of decreased lattice strain. Photovoltaic devices incorporating optimized FA<sub>0.80</sub>MA<sub>0.15</sub>Cs<sub>0.05</sub>PbI<sub>3</sub> achieve a PCE of 24.65%, while the FA<sub>0.82</sub>MA<sub>0.05</sub>Cs<sub>0.05</sub>Rb<sub>0.08</sub>PbI<sub>3</sub> device reaches 25.53%. Stability assessments reveal exceptional durability: the quaternary device retains ≈88% of its initial PCE after 500 h under humidity exposure.
Authors
- Weihuang Lin
- Xueyi Guo (ORCID: https://orcid.org/0000-0003-0660-3024)
- Si Xiao (ORCID: https://orcid.org/0000-0002-7172-3607)
- Congtan Zhu (ORCID: https://orcid.org/0000-0002-8240-0379)
- Ying Yang (ORCID: https://orcid.org/0000-0003-4025-696X)
- Haixia Zhu (ORCID: https://orcid.org/0000-0001-9536-9588)
Institutions
- Central South University (CN)
Publication Details
- Journal
- Small
- Published
- 2025-08-14
- DOI
- https://doi.org/10.1002/smll.202506008
- Primary Topic
- Perovskite Materials and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00