Efficient and Symmetric Temperature Control in Capillary Electrophoresis II: Thermal Performance When Cooling Capillaries Are Tied Around Analytical Capillaries

Current commercially available capillary electrophoresis instruments lack centrosymmetric and efficient temperature control along the whole extend of the capillary. Here we studied the characteristics and thermal performance of a cooling system that consists of cooling capillaries (fused silica microtubes) which are tied around the complete extent of the analytical capillaries. Six cooling capillaries with only 75 µm inner diameter (320 µm outer diameter-without polyimide) were tied around the outer surface of 320 µm outer diameter analytical capillaries (also without polyimide). The tying process is detailed in a previous publication (J Sep Sci. 2025; 48: e70081. https://doi.org/10.1002/jssc.70081). The application of a pressure gradient of 0.25 bar/cm in the cooling liquid was enough to efficiently remove heat and control temperature. Very strong electric fields could be applied, producing very high and stable electric currents. Fields beyond 3500 Volts/cm were applied in a 50 µm inner diameter capillary filled with 20 mM sodium phosphate buffer solution at pH 7.20 and the coolant set at 25°C. This cooling system outperformed the two most used systems: forced air and recirculating liquid coolant in a tube with a capillary inside. The spatial steady-state temperature profiles of the systems were simulated by numerically solving the heat equation using a finite element method. The centrosymmetric temperature profile and efficiency of this cooling system was corroborated by these numerical results. An objective parameter indicating cooling asymmetry was introduced and used to quantify the superior performance of this new cooling system.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-08-01
DOI
https://doi.org/10.1002/jssc.70240
Primary Topic
Microfluidic and Capillary Electrophoresis Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient and Symmetric Temperature Control in Capillary Electrophoresis II: Thermal Performance When Cooling Capillaries Are Tied Around Analytical Capillaries

Cristian Bonatto, Lucélia A. Macedo, Tarso B. Ledur Kist
Journal of Separation Science
Microfluidic and Capillary Electrophoresis Applications
article

Efficient and Symmetric Temperature Control in Capillary Electrophoresis II: Thermal Performance When Cooling Capillaries Are Tied Around Analytical Capillaries

Cristian Bonatto, Lucélia A. Macedo, Tarso B. Ledur Kist
article en

Abstract

Current commercially available capillary electrophoresis instruments lack centrosymmetric and efficient temperature control along the whole extend of the capillary. Here we studied the characteristics and thermal performance of a cooling system that consists of cooling capillaries (fused silica microtubes) which are tied around the complete extent of the analytical capillaries. Six cooling capillaries with only 75 µm inner diameter (320 µm outer diameter-without polyimide) were tied around the outer surface of 320 µm outer diameter analytical capillaries (also without polyimide). The tying process is detailed in a previous publication (J Sep Sci. 2025; 48: e70081. https://doi.org/10.1002/jssc.70081). The application of a pressure gradient of 0.25 bar/cm in the cooling liquid was enough to efficiently remove heat and control temperature. Very strong electric fields could be applied, producing very high and stable electric currents. Fields beyond 3500 Volts/cm were applied in a 50 µm inner diameter capillary filled with 20 mM sodium phosphate buffer solution at pH 7.20 and the coolant set at 25°C. This cooling system outperformed the two most used systems: forced air and recirculating liquid coolant in a tube with a capillary inside. The spatial steady-state temperature profiles of the systems were simulated by numerically solving the heat equation using a finite element method. The centrosymmetric temperature profile and efficiency of this cooling system was corroborated by these numerical results. An objective parameter indicating cooling asymmetry was introduced and used to quantify the superior performance of this new cooling system.

Journal of Separation ScienceVol. 48(8)
Universidade Federal do Rio Grande do Sul (BR), Universidade de São Paulo (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Universidade Federal do Rio Grande do Sul
Affordable and clean energy
Openalex Percentile: Top 81%
Microfluidic and Capillary Electrophoresis Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.