Rapid and Direct Determination of Methanol in Alcoholic Beverages by Ion Mobility Spectrometry

This work introduces a new method for direct detection of methanol in alcoholic beverages, using ion mobility spectrometry (IMS), headspace sampling (HS), and Tenax adsorbent preseparation (HS-Tenax-IMS). An ionization method based on the dopant gases was employed to overcome the overlapping of the reactant ions with the methanol peak. Six different ketones dopants were tested, and 2-heptanone was selected as the optimal variant. Tenax-GR column was used for both HS and as a preseparation method of methanol and ethanol prior to IMS detection. The optimum sampling time of 15 min was achieved, and analysis time was less than 1 min. The linear range for detection of methanol in solution was from 0.08% to 1.0%, corresponding to 630-7900 mg/L (<i>R</i><sup>2</sup> = 0.996). The obtained limit of quantification (LOQ) of 630 mg/L and limit of detection (LOD) of 210 mg/L are sufficient for efficient methanol detection in the food industry.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-08-12
DOI
https://doi.org/10.1021/acs.analchem.5c03428
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid and Direct Determination of Methanol in Alcoholic Beverages by Ion Mobility Spectrometry

Vahideh Ilbeigi, Younes Valadbeigi, Štefan Matejčík
1 links
Analytical Chemistry
Advanced Chemical Sensor Technologies
article

Rapid and Direct Determination of Methanol in Alcoholic Beverages by Ion Mobility Spectrometry

Vahideh Ilbeigi, Younes Valadbeigi, Štefan Matejčík
article en

Abstract

This work introduces a new method for direct detection of methanol in alcoholic beverages, using ion mobility spectrometry (IMS), headspace sampling (HS), and Tenax adsorbent preseparation (HS-Tenax-IMS). An ionization method based on the dopant gases was employed to overcome the overlapping of the reactant ions with the methanol peak. Six different ketones dopants were tested, and 2-heptanone was selected as the optimal variant. Tenax-GR column was used for both HS and as a preseparation method of methanol and ethanol prior to IMS detection. The optimum sampling time of 15 min was achieved, and analysis time was less than 1 min. The linear range for detection of methanol in solution was from 0.08% to 1.0%, corresponding to 630-7900 mg/L (<i>R</i><sup>2</sup> = 0.996). The obtained limit of quantification (LOQ) of 630 mg/L and limit of detection (LOD) of 210 mg/L are sufficient for efficient methanol detection in the food industry.

Analytical ChemistryVol. 97(33)
Imam Khomeini International University (IR), Comenius University Bratislava (SK)
Agentúra na Podporu Výskumu a Vývoja, Vedecká Grantová Agentúra MŠVVaŠ SR a SAV
Openalex Percentile: Top 81%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rapid and Direct Determination of Methanol in Alcoholic Beverages by Ion Mobility Spectrometry — Vahideh Ilbeigi, Younes Valadbeigi, et al. · Analytical Chemistry (2025) | TGRS Research Map | TGRS