Assessing the generalisation of artificial intelligence across mammography manufacturers

The aim of this study was to determine whether differences between manufacturer of mammogram images effects performance of artificial intelligence tools for classifying breast density. Processed mammograms from 10,156 women were used to train and validate three deep learning algorithms using three retrospective datasets: Hologic, General Electric, Mixed (equal numbers of Hologic, General Electric and Siemens images) and tested on four independent witheld test sets (Hologic, General Electric, Mixed and Siemens). The area under the receiver operating characteristic curve (AUC) was compared. Women aged 47-73 with normal breasts (routine recall - no cancer) and Volpara ground truth were selected from the OPTIMAM Mammography Image Database for the years 2012-2015. 95 % confidence intervals are used for significance testing in the results with a Bayesian Signed Rank test used to rank the overall performance of the models. Best single test performance is seen when a model is trained and tested on images from a single manufacturer (Hologic train/test: 0.98 and General Electric train/test: 0.97), however the same models performed significantly worse on any other manufacturer images (General Electric AUCs: 0.68 & 0.63; Hologic AUCs: 0.56 & 0.90). The model trained on the mixed dataset exhibited the best overall performance. Better performance occurs when training and test sets contain the same manufacturer distributions and better generalisation occurs when more manufacturers are included in training. Models in clinical use should be trained on data representing the different vendors of mammogram machines used across screening programs. This is clinically relevant as models will be impacted by changes and upgrades to mammogram machines in screening centres.

Authors

Institutions

Publication Details

Journal
PLOS Digital Health
Published
2025-08-12
DOI
https://doi.org/10.1371/journal.pdig.0000973
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing the generalisation of artificial intelligence across mammography manufacturers

Lucy M. Warren, A.L. Hickman, Nadia Smith, C. Shenton‐Taylor et al.
PLOS Digital Health
AI in cancer detection
article

Assessing the generalisation of artificial intelligence across mammography manufacturers

Lucy M. Warren, A.L. Hickman, Nadia Smith, C. Shenton‐Taylor, Sandra Gomes
article en

Abstract

The aim of this study was to determine whether differences between manufacturer of mammogram images effects performance of artificial intelligence tools for classifying breast density. Processed mammograms from 10,156 women were used to train and validate three deep learning algorithms using three retrospective datasets: Hologic, General Electric, Mixed (equal numbers of Hologic, General Electric and Siemens images) and tested on four independent witheld test sets (Hologic, General Electric, Mixed and Siemens). The area under the receiver operating characteristic curve (AUC) was compared. Women aged 47-73 with normal breasts (routine recall - no cancer) and Volpara ground truth were selected from the OPTIMAM Mammography Image Database for the years 2012-2015. 95 % confidence intervals are used for significance testing in the results with a Bayesian Signed Rank test used to rank the overall performance of the models. Best single test performance is seen when a model is trained and tested on images from a single manufacturer (Hologic train/test: 0.98 and General Electric train/test: 0.97), however the same models performed significantly worse on any other manufacturer images (General Electric AUCs: 0.68 & 0.63; Hologic AUCs: 0.56 & 0.90). The model trained on the mixed dataset exhibited the best overall performance. Better performance occurs when training and test sets contain the same manufacturer distributions and better generalisation occurs when more manufacturers are included in training. Models in clinical use should be trained on data representing the different vendors of mammogram machines used across screening programs. This is clinically relevant as models will be impacted by changes and upgrades to mammogram machines in screening centres.

PLOS Digital HealthVol. 4(8)
National Physical Laboratory (GB), University of Surrey (GB), Royal Surrey NHS Foundation Trust (GB)
University of Surrey
Openalex Percentile: Top 90%
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.