First evidence of coexistence of Pseudo Pelger Huet anomaly and balanced translocation in a two decades retrospectively exposed human subject

This study investigated the long-term stability of cytogenetic and morphological markers, including dicentric chromosomes (DC), unbalanced translocation (UT), balanced translocation (BT), and Pseudo Pelger-Huët Anomaly (PPHA), in a radiation worker exposed to an acute dose of <sup>60</sup>Co-γ radiation. Initial dose assessment, one week after exposure via Thermoluminescent dosimeters (TLDs) and DC, yielded a physical dose of 438.8 mGy and a biological dose of 398 mGy respectively. A follow-up biodosimetry evaluation, conducted 24 years postexposure, yielded a dose estimate of 449 mGy on the basis of BT, closely matching the initial TLD measurement (+ 2.3% relative error). In contrast, the DC, UT, and micronuclei (MN) frequencies fell within the background range, confirming their instability over time. We also assessed the presence of PPHA in blood smears from the same volunteer. PPHA, a morphological marker of neutrophils originating exclusively in vivo from bone marrow progenitor cells, demonstrated a more than twofold increase in frequency compared to background levels, suggesting an association with radiation exposure. This is the first report of concurrent BT and PPHA persistence in the same individual, demonstrating the suitability of these biomarkers for retrospective detection of past radiation exposure. BT offered reliable dose reconstruction decades after exposure. We could not translate the PPHA yield into an absorbed dose, as no in-house dose‒response curve was established.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-11
DOI
https://doi.org/10.1038/s41598-025-14858-4
Citations
3
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
4.56

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

First evidence of coexistence of Pseudo Pelger Huet anomaly and balanced translocation in a two decades retrospectively exposed human subject

Arshad Khan, Balvinder Kaur Sapra, Nagesh Bhat, Anjana Goel et al.
3 citations
Scientific Reports
Radiation Therapy and Dosimetry
4.56
article

First evidence of coexistence of Pseudo Pelger Huet anomaly and balanced translocation in a two decades retrospectively exposed human subject

Arshad Khan, Balvinder Kaur Sapra, Nagesh Bhat, Anjana Goel, Rajesh Kumar Chaurasia, R. S. Pathak, Kapil B. Shirsath
article en
3 citations

Abstract

This study investigated the long-term stability of cytogenetic and morphological markers, including dicentric chromosomes (DC), unbalanced translocation (UT), balanced translocation (BT), and Pseudo Pelger-Huët Anomaly (PPHA), in a radiation worker exposed to an acute dose of <sup>60</sup>Co-γ radiation. Initial dose assessment, one week after exposure via Thermoluminescent dosimeters (TLDs) and DC, yielded a physical dose of 438.8 mGy and a biological dose of 398 mGy respectively. A follow-up biodosimetry evaluation, conducted 24 years postexposure, yielded a dose estimate of 449 mGy on the basis of BT, closely matching the initial TLD measurement (+ 2.3% relative error). In contrast, the DC, UT, and micronuclei (MN) frequencies fell within the background range, confirming their instability over time. We also assessed the presence of PPHA in blood smears from the same volunteer. PPHA, a morphological marker of neutrophils originating exclusively in vivo from bone marrow progenitor cells, demonstrated a more than twofold increase in frequency compared to background levels, suggesting an association with radiation exposure. This is the first report of concurrent BT and PPHA persistence in the same individual, demonstrating the suitability of these biomarkers for retrospective detection of past radiation exposure. BT offered reliable dose reconstruction decades after exposure. We could not translate the PPHA yield into an absorbed dose, as no in-house dose‒response curve was established.

Scientific ReportsVol. 15(1)
Bhabha Atomic Research Centre (IN), Homi Bhabha National Institute (IN), Bhabha Atomic Research Center Hospital (IN), GLA University (IN)
Bhabha Atomic Research Centre
Good health and well-being
Openalex Percentile: Top 5%
Radiation Therapy and Dosimetry
4.56
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.