Design and upgrades of the TCV fast ion loss detector

The Tokamak à Configuration Variable has a unique Fast Ion Loss Detector (FILD) that allows the simultaneous measurement of co- and counter-current fast-ion losses in forward or reverse magnetic field. Recently, multiple novel upgrades have been implemented that further extended its capabilities. The optical system throughput was improved by adding anti-reflective coatings to the internal components, in direct view of the camera, and installing a low wavelength filter to reduce unwanted stray light. The mechanical rigidity was increased by adding additional contact points closer to the heat shield, which significantly reduced the system vibration amplitude during operation. The entrance slit pinholes were reduced from 1 to 0.8 mm, obtaining an energy resolution improvement of over 40% for only an ∼20% signal level decrease. Finally, a rotary system now permits the FILD head angle to be scanned from ±30° on a shot-to-shot basis. These upgrades, described herein, greatly increase the functionality of the FILD diagnostic.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2025-08-01
DOI
https://doi.org/10.1063/5.0266542
Citations
2
Primary Topic
Magnetic confinement fusion research
Type
article
Field-Weighted Citation Impact
3.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and upgrades of the TCV fast ion loss detector

J. Poley-Sanjuán, Y. Andrèbe, P. Lavanchy, A. Fasoli et al.
2 citations
Review of Scientific Instruments
Magnetic confinement fusion research
3.74
article

Design and upgrades of the TCV fast ion loss detector

J. Poley-Sanjuán, Y. Andrèbe, P. Lavanchy, A. Fasoli, A. Karpushov, M. Vallar, M. Toussaint, B.P. Duval, A. Jansen van Vuuren, A. Clément
article en
2 citations

Abstract

The Tokamak à Configuration Variable has a unique Fast Ion Loss Detector (FILD) that allows the simultaneous measurement of co- and counter-current fast-ion losses in forward or reverse magnetic field. Recently, multiple novel upgrades have been implemented that further extended its capabilities. The optical system throughput was improved by adding anti-reflective coatings to the internal components, in direct view of the camera, and installing a low wavelength filter to reduce unwanted stray light. The mechanical rigidity was increased by adding additional contact points closer to the heat shield, which significantly reduced the system vibration amplitude during operation. The entrance slit pinholes were reduced from 1 to 0.8 mm, obtaining an energy resolution improvement of over 40% for only an ∼20% signal level decrease. Finally, a rotary system now permits the FILD head angle to be scanned from ±30° on a shot-to-shot basis. These upgrades, described herein, greatly increase the functionality of the FILD diagnostic.

Review of Scientific InstrumentsVol. 96(8)
École Polytechnique Fédérale de Lausanne (CH)
EUROfusion, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
Affordable and clean energy
Openalex Percentile: Top 7%
Magnetic confinement fusion research
3.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Design and upgrades of the TCV fast ion loss detector — J. Poley-Sanjuán, Y. Andrèbe, et al. · Review of Scientific Instruments (2025) | TGRS Research Map | TGRS