Machine Learning for Enhanced Identification Probability in RPLC/HRMS Nontargeted Workflows

In HRMS-based nontargeted analysis (NTA), spectral matching is crucial for chemical identification, particularly in the absence of retention information. This study introduces class probability of true positives (<i>P</i>(<i>TP</i>)) as an innovative approach, leveraging data from MS/MS spectra and calibrant-free predicted retention time indices (RTIs) through 3 machine learning (ML) models to enhance identification probability (IP). The first model is a molecular fingerprint (MF)-to-RTI model trained on 4713 calibrants. The second model, a cumulative neutral loss (CNL)-to-RTI model, utilized 485,577 experimental spectra. The final model, a binary classification model, was trained using 1,686,319 <i>TP</i> and semisynthetic true negative (<i>TN</i>) spectral matches. High correlations between MF-derived and CNL-derived RTI values (<i>R</i><sup>2</sup> = 0.96 for training; 0.88 for testing) suggest reduced RTI errors in <i>TP</i> spectral matches. Incorporating reference spectral library searches and RTI errors, the k-nearest neighbors algorithm achieved a weighted <i>F</i>1 score of 0.65 and a Matthews correlation coefficient of 0.30 for pesticides at concentrations of 1 to 1000 ppb in blank samples, with a recall of 0.60 in black tea matrices. Compared to solely library matching, the average IPs for pesticides increased by 54.5, 52.1, and 46.7% when spiked in blank, 10× diluted, and 100× diluted tea matrices, respectively. This work demonstrates the effectiveness of ML in enhancing the chemical IPs of annotated compounds within complex matrices.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-08-12
DOI
https://doi.org/10.1021/acs.analchem.5c01873
Primary Topic
Metabolomics and Mass Spectrometry Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine Learning for Enhanced Identification Probability in RPLC/HRMS Nontargeted Workflows

Denice van Herwerden, Hiu‐Lok Ngan, Saer Samanipour, Zongwei Cai et al.
Analytical Chemistry
Metabolomics and Mass Spectrometry Studies
article

Machine Learning for Enhanced Identification Probability in RPLC/HRMS Nontargeted Workflows

Denice van Herwerden, Hiu‐Lok Ngan, Saer Samanipour, Zongwei Cai, Yan Hong, Viktoriia Turkina
article en

Abstract

In HRMS-based nontargeted analysis (NTA), spectral matching is crucial for chemical identification, particularly in the absence of retention information. This study introduces class probability of true positives (<i>P</i>(<i>TP</i>)) as an innovative approach, leveraging data from MS/MS spectra and calibrant-free predicted retention time indices (RTIs) through 3 machine learning (ML) models to enhance identification probability (IP). The first model is a molecular fingerprint (MF)-to-RTI model trained on 4713 calibrants. The second model, a cumulative neutral loss (CNL)-to-RTI model, utilized 485,577 experimental spectra. The final model, a binary classification model, was trained using 1,686,319 <i>TP</i> and semisynthetic true negative (<i>TN</i>) spectral matches. High correlations between MF-derived and CNL-derived RTI values (<i>R</i><sup>2</sup> = 0.96 for training; 0.88 for testing) suggest reduced RTI errors in <i>TP</i> spectral matches. Incorporating reference spectral library searches and RTI errors, the k-nearest neighbors algorithm achieved a weighted <i>F</i>1 score of 0.65 and a Matthews correlation coefficient of 0.30 for pesticides at concentrations of 1 to 1000 ppb in blank samples, with a recall of 0.60 in black tea matrices. Compared to solely library matching, the average IPs for pesticides increased by 54.5, 52.1, and 46.7% when spiked in blank, 10× diluted, and 100× diluted tea matrices, respectively. This work demonstrates the effectiveness of ML in enhancing the chemical IPs of annotated compounds within complex matrices.

Analytical ChemistryVol. 97(33)
Hong Kong Baptist University (HK), High Institute for Management Sciences (EG), University of Amsterdam (NL)
Openalex Percentile: Top 82%
Metabolomics and Mass Spectrometry Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.