Evaluation of dental implant with hydroxyapatite coating by laser-induced hydrothermal synthesis: in vitro and in vivo experimental study

Various surface modification techniques have been developed to improve the survival rate of dental implants. This study aimed to evaluate both in vitro and in vivo outcomes of implants coated with a nano/micro-assembled hydroxyapatite (HA) structure using a laser-induced single-step coating (LISSC) technique. Four types of implant surfaces were examined: machined surface implants (MA), sandblasted large-grit acid-etched implants (SLA), resorbable blasting media implants (RBM), and HA-coated implants (HA). In vitro analyses included surface morphology, surface hydrophilicity, and cell attachment. Twelve rabbits and two beagle dogs were used in the in vivo experiments. The implant stability quotient (ISQ) was measured immediately after placement and again at sacrifice (rabbits: 3 and 6 weeks; beagles: 12 weeks), followed by histological evaluation and quantification of bone-to-implant contact (BIC%) and bone volume (BV%). ISQ values increased from the postoperative period to 6 or 12 weeks across all implant types. In vitro, surface roughness ranked as HA > RBM > SLA > MA, while surface wettability ranked as RBM > HA > MA > SLA. No significant differences were observed in initial cell adhesion or viability among the groups. In vivo, BV ranked as MA > RBM > SLA > HA at 3 weeks, and MA > HA > RBM > SLA at 6 weeks. BIC ranked as RBM > MA > SLA > HA at 3 weeks and HA > RBM > SLA > MA at 6 weeks. HA exhibited the greatest increases in both BV and BIC from 3 to 6 weeks. In beagles, ISQ at 12 weeks was higher than baseline for both SLA and HA, with HA demonstrating superior BV compared to SLA. Within the limitations of this preclinical study, HA-coated implants produced via the LISSC method demonstrated comparable or superior biological performance relative to conventional MA, SLA, and RBM surfaces.

Authors

Institutions

Publication Details

Journal
Discover Nano
Published
2025-08-12
DOI
https://doi.org/10.1186/s11671-025-04330-7
Citations
2
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
3.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of dental implant with hydroxyapatite coating by laser-induced hydrothermal synthesis: in vitro and in vivo experimental study

Bongju Kim, Keonhee Lee, Kyung-Woo Lee, Hojeong Jeon et al.
2 citations
Discover Nano
Dental Implant Techniques and Outcomes
3.58
article

Evaluation of dental implant with hydroxyapatite coating by laser-induced hydrothermal synthesis: in vitro and in vivo experimental study

Bongju Kim, Keonhee Lee, Kyung-Woo Lee, Hojeong Jeon, Jung‐Tae Lee, Tae‐Gon Jung, Sung-Ho Lee, Dong‐Wook Han, Sungtae Kim, Sangyun Lee, Daehyeok Kwon
article en
2 citations

Abstract

Various surface modification techniques have been developed to improve the survival rate of dental implants. This study aimed to evaluate both in vitro and in vivo outcomes of implants coated with a nano/micro-assembled hydroxyapatite (HA) structure using a laser-induced single-step coating (LISSC) technique. Four types of implant surfaces were examined: machined surface implants (MA), sandblasted large-grit acid-etched implants (SLA), resorbable blasting media implants (RBM), and HA-coated implants (HA). In vitro analyses included surface morphology, surface hydrophilicity, and cell attachment. Twelve rabbits and two beagle dogs were used in the in vivo experiments. The implant stability quotient (ISQ) was measured immediately after placement and again at sacrifice (rabbits: 3 and 6 weeks; beagles: 12 weeks), followed by histological evaluation and quantification of bone-to-implant contact (BIC%) and bone volume (BV%). ISQ values increased from the postoperative period to 6 or 12 weeks across all implant types. In vitro, surface roughness ranked as HA > RBM > SLA > MA, while surface wettability ranked as RBM > HA > MA > SLA. No significant differences were observed in initial cell adhesion or viability among the groups. In vivo, BV ranked as MA > RBM > SLA > HA at 3 weeks, and MA > HA > RBM > SLA at 6 weeks. BIC ranked as RBM > MA > SLA > HA at 3 weeks and HA > RBM > SLA > MA at 6 weeks. HA exhibited the greatest increases in both BV and BIC from 3 to 6 weeks. In beagles, ISQ at 12 weeks was higher than baseline for both SLA and HA, with HA demonstrating superior BV compared to SLA. Within the limitations of this preclinical study, HA-coated implants produced via the LISSC method demonstrated comparable or superior biological performance relative to conventional MA, SLA, and RBM surfaces.

Discover NanoVol. 20(1)
Seoul National University (KR), Osstem Implant (South Korea) (KR), Seoul National University Dental Hospital (KR), Pusan National University (KR), Korea Institute of Science and Technology (KR)
Korea Medical Device Development Fund, Ministry of Trade, Industry and Energy, Ministry of Food and Drug Safety, Ministry of SMEs and Startups, Ministry of Science and ICT, South Korea
Clean water and sanitation, Life below water
Openalex Percentile: Top 7%
Dental Implant Techniques and Outcomes
3.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.