Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error

The rotor system is a crucial component in the design and manufacture of helicopters. Accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this paper presents a rotor balance based on the piezoelectric measurement principle for precise measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Secondly, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Instrumentation and Measurement
Published
2025-01-01
DOI
https://doi.org/10.1109/tim.2025.3593559
Primary Topic
Advanced Measurement and Detection Methods
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error

Zongjin Ren, Jinlong Liu, Yucen Li, Jun Zhang et al.
IEEE Transactions on Instrumentation and Measurement
Advanced Measurement and Detection Methods
article

Performance Study of the Six-Component Piezoelectric Helicopter Rotor Balance Vector Test System Considering the Influence of Assembly Error

Zongjin Ren, Jinlong Liu, Yucen Li, Jun Zhang, Yaqi Wu, Jin Wang, Xinyang Li, Wei Liu, Jialing Wu
article en

Abstract

The rotor system is a crucial component in the design and manufacture of helicopters. Accurate measurement of the output aerodynamic forces of the rotor system is indispensable to ensure high maneuverability and stability of the aircraft during service. To overcome the challenge of measuring the high-frequency harmonic loads on rotor blades due to their rotation, this paper presents a rotor balance based on the piezoelectric measurement principle for precise measurement of rotor dynamic loads. This device adopts a planar four-point support structure, featuring high precision, high rigidity, and fast response speed. By establishing a theoretical mechanical model of the piezoelectric balance and analyzing and decoupling its force state, the main factors influencing its performance variations are obtained. Secondly, in response to the uneven height issue existing in the assembly process of piezoelectric components, ANSYS simulation software was utilized to conduct overall parameter optimization and investigate the influence of assembly errors. Additionally, modal and static simulation analyses were carried out to finalize the overall optimization plan for the measurement device. Additionally, a self-developed three-direction force calibration device is employed to conduct static calibration and exploration of the natural frequency of four piezoelectric elements and the balance system. The static and dynamic performance of the rotor vector measurement system has been verified through experiments, and it meets the test requirements. The linearity and repeatability errors of all forces and moments are less than 1.00%, and the natural frequency is higher than 900 Hz. This device can offer theoretical basis and reference for subsequent high-precision measurement of rotor systems and the design of balances.

IEEE Transactions on Instrumentation and MeasurementVol. 74
Dalian University of Technology (CN), Dalian University (CN)
National Natural Science Foundation of China
Affordable and clean energy
Openalex Percentile: Top 82%
Advanced Measurement and Detection Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.