Triaxial Micro Force Plate Array for Measuring Ground Reaction Force in Ant Locomotion

Terrestrial insects such as ants are known for their agile locomotion on six legs. However, the ground reaction force (GRF) of each leg has not been well characterized due to its difficulty in measurement. In this report, a micro force plate array is presented that uses the Sampling Moiré (SM) method, a prism, and a single camera to simultaneously measure the triaxial GRFs of multiple legs of an ant during its locomotion. The SM method is a high-resolution measurement method that measures the amount of displacement based on the shift of a captured grid pattern. The proposed micro force plate array consists of a 3 × 3 array of 2900 × 2900 × 70 μm plate bases with a gap of 100 μm as the contact surface of the ant legs. The plate base is supported by a spring structure with a grid pattern. By capturing this grid pattern from the backside via a prism, a camera can capture images from two different directions, allowing the triaxial displacement to be measured. By dividing the plate surface into nine sections and evaluating the error based on the position of the force application in the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z</i>-direction force, a maximum measurement error of 6% was found. The average force resolution in the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</i>, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</i>, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z</i> directions for the 9 plates were 3.34, 2.47, and 1.20 μN, respectively. With the developed force plate array, it was possible to measure the GRF of each leg simultaneously while the ant was walking.

Authors

Institutions

Publication Details

Journal
IEEE Sensors Journal
Published
2025-08-11
DOI
https://doi.org/10.1109/jsen.2025.3595999
Citations
2
Primary Topic
Robotic Locomotion and Control
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Triaxial Micro Force Plate Array for Measuring Ground Reaction Force in Ant Locomotion

Hidetoshi Takahashi, Toshihiro Shiratori
2 citations
IEEE Sensors Journal
Robotic Locomotion and Control
1.35
article

Triaxial Micro Force Plate Array for Measuring Ground Reaction Force in Ant Locomotion

Hidetoshi Takahashi, Toshihiro Shiratori
article en
2 citations

Abstract

Terrestrial insects such as ants are known for their agile locomotion on six legs. However, the ground reaction force (GRF) of each leg has not been well characterized due to its difficulty in measurement. In this report, a micro force plate array is presented that uses the Sampling Moiré (SM) method, a prism, and a single camera to simultaneously measure the triaxial GRFs of multiple legs of an ant during its locomotion. The SM method is a high-resolution measurement method that measures the amount of displacement based on the shift of a captured grid pattern. The proposed micro force plate array consists of a 3 × 3 array of 2900 × 2900 × 70 μm plate bases with a gap of 100 μm as the contact surface of the ant legs. The plate base is supported by a spring structure with a grid pattern. By capturing this grid pattern from the backside via a prism, a camera can capture images from two different directions, allowing the triaxial displacement to be measured. By dividing the plate surface into nine sections and evaluating the error based on the position of the force application in the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z</i>-direction force, a maximum measurement error of 6% was found. The average force resolution in the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">x</i>, <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">y</i>, and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">z</i> directions for the 9 plates were 3.34, 2.47, and 1.20 μN, respectively. With the developed force plate array, it was possible to measure the GRF of each leg simultaneously while the ant was walking.

IEEE Sensors JournalVol. 25(18)
Keio University (JP)
Openalex Percentile: Top 18%
Robotic Locomotion and Control
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Triaxial Micro Force Plate Array for Measuring Ground Reaction Force in Ant Locomotion — Hidetoshi Takahashi, Toshihiro Shiratori · IEEE Sensors Journal (2025) | TGRS Research Map | TGRS