Exosome Biosensor Based on Quantum Dots-Modified Field Effect Transistor
The escalating demand for high-throughput and miniaturized biosensors has spurred significant advancements in biosensor chips. However, challenges remain in achieving high sensitivity and specificity in miniaturized devices. Herein, we construct a sensitive exosome biosensor based on quantum dots (QDs)-modified field effect transistor. PbS QDs were drop-coated onto the gate of a high electron mobility transistor (HEMT), followed by surface modification with CD63 antibodies (anti-CD63) through a ligand exchange strategy, and subsequent bovine serum albumin (BSA) blocking treatment. Exosomes with CD63 proteins enriched in the surface were isolated from MCF-7 breast cancer cell lines to serve as target analytes. The specific binding events between CD63 antigen and antibody capture exosomes onto the gate of HEMT, affecting the output current (<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">D</sub>). The synergy of the capacitance coupling effect of the modification layer and the intrinsic signal amplification capability of HEMT assists in significantly modulating the two-dimensional electron gas (2DEG), resulting in amplified <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">D</sub>. With constant gate voltage applied, the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">I</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">D</sub> of the biosensor sensitively increases with exosome concentration within a wide range of 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">5</sup>-10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">9</sup> particles/mL at <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">V</i><sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">D</sub> = 3.5 V, and the LOD is estimated to be 9 × 10<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sup> particles/mL. This exosome biosensor demonstrates its potential for clinical applicability and paves the way for the development of miniaturized exosome biosensor chips.
Authors
- Qing Huang (ORCID: https://orcid.org/0000-0002-1022-7714)
- Lanpeng Guo (ORCID: https://orcid.org/0000-0002-9960-3631)
- Hua‐Yao Li (ORCID: https://orcid.org/0000-0003-2646-3313)
- Liang Hu
- Tucan Chen (ORCID: https://orcid.org/0000-0002-5594-5162)
- Yunong Zhao (ORCID: https://orcid.org/0000-0003-2439-8669)
- Huan Liu (ORCID: https://orcid.org/0000-0002-4222-2299)
- Yang Zhang (ORCID: https://orcid.org/0000-0002-3002-4367)
- Dandan Li (ORCID: https://orcid.org/0000-0002-2100-4145)
- Jing Huang (ORCID: https://orcid.org/0000-0003-2870-8687)
- Wenjian Zhang (ORCID: https://orcid.org/0000-0002-3524-3841)
- Jingqiu Chen
Institutions
- Chinese Academy of Sciences (CN)
- Wenzhou Medical University (CN)
- Jianghan University (CN)
- Affiliated Eye Hospital of Wenzhou Medical College (CN)
- Wuhan National Laboratory for Optoelectronics (CN)
- Institute of Semiconductors (CN)
- Huazhong University of Science and Technology (CN)
Publication Details
- Journal
- IEEE Sensors Journal
- Published
- 2025-08-11
- DOI
- https://doi.org/10.1109/jsen.2025.3593869
- Primary Topic
- Nanowire Synthesis and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- Natural Science Foundation of Hubei Province
- Natural Science Foundation of Zhejiang Province