Planning and Compliant Control for Laparoscopic Ultrasound Scanning System

Laparoscopic ultrasound (LUS) serves as a critical technology in intraoperative surgeries, particularly for guiding complex procedures in liver diseases. However, the development of robotic systems for LUS examination remains hindered by challenges such as high costs and the absence of force feedback capabilities. In this study, we develop an 8-degree-of-freedom (DOF) LUS scanning system, which integrates a flexible manipulator and a force-sensing probe fixture to achieve precise position adjustment and real-time force feedback. A geometry-based coordinate alignment method is proposed under remote centre of motion (RCM) constraints to ensure safe operational execution. In addition, in accordance with the estimated contact force from a neural network, a compliant force controller is designed to achieve high-quality ultrasound imaging. Experimental results validate the motion planning under the RCM constraint, yielding a maximum root mean square error (RMSE) of 0.767 mm, whereas contact force tracking achieved a maximum RMSE of 0.037 N. Furthermore, experiments on phantom models confirmed the effectiveness of the proposed approach, which was further validated on in vitro porcine liver to demonstrate its clinical potential.

Authors

Institutions

Publication Details

Journal
IEEE Robotics and Automation Letters
Published
2025-08-11
DOI
https://doi.org/10.1109/lra.2025.3597832
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Planning and Compliant Control for Laparoscopic Ultrasound Scanning System

Renan Jin, Sheng‐Xiang Qiu, Jian Chen, Jingyu Zhang et al.
IEEE Robotics and Automation Letters
Surgical Simulation and Training
article

Planning and Compliant Control for Laparoscopic Ultrasound Scanning System

Renan Jin, Sheng‐Xiang Qiu, Jian Chen, Jingyu Zhang, Xiao Liang, Qihang Yang, Junjie Ge
article en

Abstract

Laparoscopic ultrasound (LUS) serves as a critical technology in intraoperative surgeries, particularly for guiding complex procedures in liver diseases. However, the development of robotic systems for LUS examination remains hindered by challenges such as high costs and the absence of force feedback capabilities. In this study, we develop an 8-degree-of-freedom (DOF) LUS scanning system, which integrates a flexible manipulator and a force-sensing probe fixture to achieve precise position adjustment and real-time force feedback. A geometry-based coordinate alignment method is proposed under remote centre of motion (RCM) constraints to ensure safe operational execution. In addition, in accordance with the estimated contact force from a neural network, a compliant force controller is designed to achieve high-quality ultrasound imaging. Experimental results validate the motion planning under the RCM constraint, yielding a maximum root mean square error (RMSE) of 0.767 mm, whereas contact force tracking achieved a maximum RMSE of 0.037 N. Furthermore, experiments on phantom models confirmed the effectiveness of the proposed approach, which was further validated on in vitro porcine liver to demonstrate its clinical potential.

IEEE Robotics and Automation LettersVol. 10(10)
Harbin Institute of Technology (CN), Sir Run Run Shaw Hospital (CN), Zhejiang University (CN)
Openalex Percentile: Top 67%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.