From analytical interference to the detection of intoxication

This article describes the case of a 66-year-old man who attended the emergency department due to a decrease in the level of consciousness. When determining creatinine in blood plasma using the enzymatic method on the Roche cobas c702® (Roche Diagnostics, Manheim, Germany), an undetectable creatinine value was obtained. Recently, both the literature and the manufacturer of the assay have described that the toxic metabolite of paracetamol, N-acetyl-p-benzoquinone imine, interferes with the enzymatic measurement of creatinine. Therefore, the concentration of paracetamol was determined in the same sample confirming toxic levels. On the other hand, the determination of creatinine by the Jaffe method did not present such interference. This case underlines the importance of determining creatinine by non-enzymatic methods in cases of paracetamol overdose in order to correctly assess renal function.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2025-08-12
DOI
https://doi.org/10.1177/00045632251367247
Citations
1
Primary Topic
Renal function and acid-base balance
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

From analytical interference to the detection of intoxication

Sergio Luis‐Lima, Fuensanta Gómez-Bernal, Marı́a José de la Vega-Prieto, Sonali Suresh Karnani-Khemlani et al.
1 citations
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Renal function and acid-base balance
1.43
article

From analytical interference to the detection of intoxication

Sergio Luis‐Lima, Fuensanta Gómez-Bernal, Marı́a José de la Vega-Prieto, Sonali Suresh Karnani-Khemlani, Juana Reyes Padrón-Morales, Elene Laburu-Dañobeitia, Marta Rodríguez-García, Darío Cabana-Ramos
article en
1 citations

Abstract

This article describes the case of a 66-year-old man who attended the emergency department due to a decrease in the level of consciousness. When determining creatinine in blood plasma using the enzymatic method on the Roche cobas c702® (Roche Diagnostics, Manheim, Germany), an undetectable creatinine value was obtained. Recently, both the literature and the manufacturer of the assay have described that the toxic metabolite of paracetamol, N-acetyl-p-benzoquinone imine, interferes with the enzymatic measurement of creatinine. Therefore, the concentration of paracetamol was determined in the same sample confirming toxic levels. On the other hand, the determination of creatinine by the Jaffe method did not present such interference. This case underlines the importance of determining creatinine by non-enzymatic methods in cases of paracetamol overdose in order to correctly assess renal function.

Annals of Clinical Biochemistry International Journal of Laboratory MedicineVol. 63(2)
Hospital Universitario de Canarias (ES)
Good health and well-being
Openalex Percentile: Top 17%
Renal function and acid-base balance
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.