Supplementation of pyridoxal-5′-phosphate in aminotransferase reagents: a matter of patient safety

As aminotransferases represent the first-level tests to detect individuals with hepatocellular damage, standardization of their measurements is a priority need for patient care. The obtaining of the harmonization in aminotransferase results is however strongly dependent on supplementation of pyridoxal-5'-phosphate (P-5-P) in aminotransferase reagents as this exclusively enables reporting of measured values on clinical samples that are traceable to the IFCC reference measurements procedures, representing the highest metrological level defining the respective measurable enzyme quantity. The lack of P-5-P addition in the employed commercial reagents is the most frequent cause of unacceptably biased results of aminotransferases, which opposes to consistency of results across laboratories and commercial assays. Nevertheless, only about one-third of medical laboratories include P-5-P in their aminotransferase measurements. This demonstrates a lack of awareness of the clinical benefits of P-5-P supplementation, which is not just an analytical preference, but it represents a laboratory priority for providing a high-quality service in pertinent clinical situations.

Authors

Institutions

Publication Details

Journal
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2025-08-11
DOI
https://doi.org/10.1515/cclm-2025-0947
Citations
1
Primary Topic
Clinical Laboratory Practices and Quality Control
Type
article
Field-Weighted Citation Impact
1.16
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Supplementation of pyridoxal-5′-phosphate in aminotransferase reagents: a matter of patient safety

Mauro Panteghini
1 citations
Clinical Chemistry and Laboratory Medicine (CCLM)
Clinical Laboratory Practices and Quality Control
1.16
article

Supplementation of pyridoxal-5′-phosphate in aminotransferase reagents: a matter of patient safety

Mauro Panteghini
article en
1 citations

Abstract

As aminotransferases represent the first-level tests to detect individuals with hepatocellular damage, standardization of their measurements is a priority need for patient care. The obtaining of the harmonization in aminotransferase results is however strongly dependent on supplementation of pyridoxal-5'-phosphate (P-5-P) in aminotransferase reagents as this exclusively enables reporting of measured values on clinical samples that are traceable to the IFCC reference measurements procedures, representing the highest metrological level defining the respective measurable enzyme quantity. The lack of P-5-P addition in the employed commercial reagents is the most frequent cause of unacceptably biased results of aminotransferases, which opposes to consistency of results across laboratories and commercial assays. Nevertheless, only about one-third of medical laboratories include P-5-P in their aminotransferase measurements. This demonstrates a lack of awareness of the clinical benefits of P-5-P supplementation, which is not just an analytical preference, but it represents a laboratory priority for providing a high-quality service in pertinent clinical situations.

Clinical Chemistry and Laboratory Medicine (CCLM)Vol. 63(12)
Nicolaus Copernicus University (PL)
Openalex Percentile: Top 19%
Clinical Laboratory Practices and Quality Control
1.16
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.