Analysis of the value of infrared thermal imaging technology in the diagnosis of emergency pulmonary infections

To explore the value of infrared thermal imaging technology in the diagnosis of emergency pulmonary infections. 200 patients who received emergency treatment at our hospital from October 2020 to December 2021 were selected as the study subjects. General information was collected from all patients, including 108 patients with acute pulmonary infection and 92 patients without pulmonary infection. All patients were tested using infrared thermal imaging technology and infrared thermal imaging equipment, with X-ray examination as the gold standard, The chest X-ray scan was performed using an X-ray camera produced by Siemens, and the temperature difference between the affected areas detected by infrared thermal imaging technology in two groups of patients was compared. The detection rate of infrared thermal imaging in the lung infection group was analyzed, and the diagnostic efficacy was evaluated by plotting the ROC curve to calculate the area under the curve. Compared with the uninfected group, the infrared radiation temperature of the infected group was significantly increased in the body surface, chest, abdomen, bilateral lungs, and midpoint of the breasts, with a statistically significant difference (P < 0.05). The positive rate of infrared thermal imaging detection in the lung infection group was 93 cases (86.11%), and the positive rate of gold standard X-ray detection was 102 cases (94.44%), the difference is statistically significant (P < 0.05). The AUC value of infrared thermal imaging technology for detecting emergency pulmonary infection patients is 0.933, the sensitivity is 90.36%, the specificity is 92.28%, and the Jordan index is 0.92. Infrared thermography has important applications in the diagnosis of lung infections in emergency medicine.It can reflect the distribution range of abnormal hot spots in patients' lung infections by evaluating temperature changes, and has good diagnostic value in clinical practice.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-10
DOI
https://doi.org/10.1038/s41598-025-15123-4
Primary Topic
Infrared Thermography in Medicine
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of the value of infrared thermal imaging technology in the diagnosis of emergency pulmonary infections

Zhanzheng Yang, Fangge Deng, Zanfeng Cao, Hongjiao Nie et al.
Scientific Reports
Infrared Thermography in Medicine
article

Analysis of the value of infrared thermal imaging technology in the diagnosis of emergency pulmonary infections

Zhanzheng Yang, Fangge Deng, Zanfeng Cao, Hongjiao Nie, Xiaoying Chen, Zuopeng Zhang, Zhixin Wu
article en

Abstract

To explore the value of infrared thermal imaging technology in the diagnosis of emergency pulmonary infections. 200 patients who received emergency treatment at our hospital from October 2020 to December 2021 were selected as the study subjects. General information was collected from all patients, including 108 patients with acute pulmonary infection and 92 patients without pulmonary infection. All patients were tested using infrared thermal imaging technology and infrared thermal imaging equipment, with X-ray examination as the gold standard, The chest X-ray scan was performed using an X-ray camera produced by Siemens, and the temperature difference between the affected areas detected by infrared thermal imaging technology in two groups of patients was compared. The detection rate of infrared thermal imaging in the lung infection group was analyzed, and the diagnostic efficacy was evaluated by plotting the ROC curve to calculate the area under the curve. Compared with the uninfected group, the infrared radiation temperature of the infected group was significantly increased in the body surface, chest, abdomen, bilateral lungs, and midpoint of the breasts, with a statistically significant difference (P < 0.05). The positive rate of infrared thermal imaging detection in the lung infection group was 93 cases (86.11%), and the positive rate of gold standard X-ray detection was 102 cases (94.44%), the difference is statistically significant (P < 0.05). The AUC value of infrared thermal imaging technology for detecting emergency pulmonary infection patients is 0.933, the sensitivity is 90.36%, the specificity is 92.28%, and the Jordan index is 0.92. Infrared thermography has important applications in the diagnosis of lung infections in emergency medicine.It can reflect the distribution range of abnormal hot spots in patients' lung infections by evaluating temperature changes, and has good diagnostic value in clinical practice.

Scientific ReportsVol. 15(1)
First Affiliated Hospital of Guangzhou Medical University (CN), Guangzhou Medical University (CN)
Good health and well-being
Openalex Percentile: Top 71%
Infrared Thermography in Medicine
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.