Implicit neural representation for scalable 3D reconstruction from sparse ultrasound images

Although volumetric ultrasound is limited by cost and availability of 2D arrays, 3D volumes can be reconstructed from 2D slices if transducer position is known, which is not usually the case. Even with position data, existing algorithms for reconstruction are impractical due to their discrete nature that struggles with scale. We propose a 1D array on a programmable motor for scanning and implicit neural representations for continuous reconstruction. Our network's ability to sample at arbitrary positions was compared to classic algorithms, achieving x7.9 performance while maintaining accuracy. Based on these, a reconstruction pipeline was tested on simulated data with 93% accuracy using only 36 B-mode images. This was evaluated in-vivo to measure tumor volumes in mice, with 6.3% mean error. Our findings suggest implicit neural representations can reduce data needed to recreate volumes from 2D slices and replace interpolation methods to enable interactive analysis.

Authors

Institutions

Publication Details

Journal
npj Acoustics
Published
2025-08-08
DOI
https://doi.org/10.1038/s44384-025-00018-5
Citations
2
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
2.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implicit neural representation for scalable 3D reconstruction from sparse ultrasound images

Bar Glickstein, Tali Ilovitsh, Tal Grutman, Mike Bismuth
2 citations
npj Acoustics
Ultrasound Imaging and Elastography
2.72
article

Implicit neural representation for scalable 3D reconstruction from sparse ultrasound images

Bar Glickstein, Tali Ilovitsh, Tal Grutman, Mike Bismuth
article en
2 citations

Abstract

Although volumetric ultrasound is limited by cost and availability of 2D arrays, 3D volumes can be reconstructed from 2D slices if transducer position is known, which is not usually the case. Even with position data, existing algorithms for reconstruction are impractical due to their discrete nature that struggles with scale. We propose a 1D array on a programmable motor for scanning and implicit neural representations for continuous reconstruction. Our network's ability to sample at arbitrary positions was compared to classic algorithms, achieving x7.9 performance while maintaining accuracy. Based on these, a reconstruction pipeline was tested on simulated data with 93% accuracy using only 36 B-mode images. This was evaluated in-vivo to measure tumor volumes in mice, with 6.3% mean error. Our findings suggest implicit neural representations can reduce data needed to recreate volumes from 2D slices and replace interpolation methods to enable interactive analysis.

npj AcousticsVol. 1(1)
Tel Aviv University (IL), Academic College of Tel Aviv-Yafo (IL)
Israel Cancer Research Fund, Israel Science Foundation, Tel Aviv University, European Research Council, Nicholas and Elizabeth Slezak Super Center for Cardiac Research and Biomedical Engineering
Openalex Percentile: Top 9%
Ultrasound Imaging and Elastography
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Implicit neural representation for scalable 3D reconstruction from sparse ultrasound images — Bar Glickstein, Tali Ilovitsh, et al. · npj Acoustics (2025) | TGRS Research Map | TGRS