General anesthesia during dental treatment in a pediatric patient with Fontan circulation using a minimally invasive cardiac output monitoring device

This case report presents the hemodynamic management of a 3-year-old patient with Fontan circulation who underwent dental treatment under general anesthesia using minimally invasive cardiac output monitoring devices. To avoid the use of monitoring methods more invasive than the dental procedure itself, cardiac output was continuously assessed using FloTrac™ and BioZ.com™ systems. The bispectral index was maintained between 40 and 67 during anesthesia. Although the patient's body surface area (BSA) was 0.5 m<sup>2</sup>, which is below the validated threshold for both devices, monitoring was cautiously conducted to observe hemodynamic trends. Discrepancies in the cardiac output and index values were observed between the two modalities. Although the absolute values were less reliable owing to the patient's low BSA, hemodynamic stability was maintained by tracking the dynamic changes in cardiac parameters. These observations underscore both the limitations and the potential of noninvasive cardiac monitoring in pediatric patients with Fontan circulation undergoing general anesthesia. Accordingly, future development of monitoring technologies that can accurately measure cardiac output in pediatric patients with BSA < 1 m<sup>2</sup> is warranted.

Authors

Institutions

Publication Details

Journal
Journal of Dental Anesthesia and Pain Medicine
Published
2025-01-01
DOI
https://doi.org/10.17245/jdapm.2025.25.4.291
Primary Topic
Congenital Heart Disease Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

General anesthesia during dental treatment in a pediatric patient with Fontan circulation using a minimally invasive cardiac output monitoring device

Satoshi Saitou, Kentaro Ouchi, S Fujiwara, Yuichiro Nakamura
Journal of Dental Anesthesia and Pain Medicine
Congenital Heart Disease Studies
article

General anesthesia during dental treatment in a pediatric patient with Fontan circulation using a minimally invasive cardiac output monitoring device

Satoshi Saitou, Kentaro Ouchi, S Fujiwara, Yuichiro Nakamura
article en

Abstract

This case report presents the hemodynamic management of a 3-year-old patient with Fontan circulation who underwent dental treatment under general anesthesia using minimally invasive cardiac output monitoring devices. To avoid the use of monitoring methods more invasive than the dental procedure itself, cardiac output was continuously assessed using FloTrac™ and BioZ.com™ systems. The bispectral index was maintained between 40 and 67 during anesthesia. Although the patient's body surface area (BSA) was 0.5 m<sup>2</sup>, which is below the validated threshold for both devices, monitoring was cautiously conducted to observe hemodynamic trends. Discrepancies in the cardiac output and index values were observed between the two modalities. Although the absolute values were less reliable owing to the patient's low BSA, hemodynamic stability was maintained by tracking the dynamic changes in cardiac parameters. These observations underscore both the limitations and the potential of noninvasive cardiac monitoring in pediatric patients with Fontan circulation undergoing general anesthesia. Accordingly, future development of monitoring technologies that can accurately measure cardiac output in pediatric patients with BSA < 1 m<sup>2</sup> is warranted.

Journal of Dental Anesthesia and Pain MedicineVol. 25(4)
Kyushu University (JP), Kyushu Dental University (JP), Tokushima University Hospital (JP), The Nakamura Hajime Eastern Institute (JP), Tokushima University (JP)
Openalex Percentile: Top 72%
Congenital Heart Disease Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

General anesthesia during dental treatment in a pediatric patient with Fontan circulation using a minimally invasive cardiac output monitoring device — Satoshi Saitou, Kentaro Ouchi, et al. · Journal of Dental Anesthesia and Pain Medicine (2025) | TGRS Research Map | TGRS