The Experimental and Simulation Study of Substation Time Synchronization System Affected by Strong Electromagnetic Pulse

High-altitude Electromagnetic Pulse (HEMP), as a type of strong electromagnetic pulse, is characterized by its high energy, short rise time, wide coverage, and broad frequency range. It can couple through various cables and damage downstream electronic devices. As a strongly time-dependent system, a unified reference time is crucial for the safe and stable operation of smart substations. This paper models the time synchronization system of a substation and investigates its coupling response under HEMP. Both simulation and experimental results, which account for the environmental conditions of the time synchronization system, show good accuracy. The findings indicate that HEMP can damage the time synchronization system, causing it to lose its synchronization functionality, thereby impacting the substation.

Authors

Institutions

Publication Details

Published
2025-05-23
DOI
https://doi.org/10.1109/etae65337.2025.11089637
Primary Topic
Power Systems Fault Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Experimental and Simulation Study of Substation Time Synchronization System Affected by Strong Electromagnetic Pulse

Xuan Ou, Tuo Xin, Weizhao Huang, Qin Shang
Power Systems Fault Detection
article

The Experimental and Simulation Study of Substation Time Synchronization System Affected by Strong Electromagnetic Pulse

Xuan Ou, Tuo Xin, Weizhao Huang, Qin Shang
article en

Abstract

High-altitude Electromagnetic Pulse (HEMP), as a type of strong electromagnetic pulse, is characterized by its high energy, short rise time, wide coverage, and broad frequency range. It can couple through various cables and damage downstream electronic devices. As a strongly time-dependent system, a unified reference time is crucial for the safe and stable operation of smart substations. This paper models the time synchronization system of a substation and investigates its coupling response under HEMP. Both simulation and experimental results, which account for the environmental conditions of the time synchronization system, show good accuracy. The findings indicate that HEMP can damage the time synchronization system, causing it to lose its synchronization functionality, thereby impacting the substation.

Shenzhen Stock Exchange (CN), Xi'an Jiaotong University (CN)
Affordable and clean energy
Openalex Percentile: Top 76%
Power Systems Fault Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.