PFAS screening in municipal wastewater effluents and mixed liquor – using TOP assay as a sum parameter

Wastewater treatment plants (WWTPs) are a point source for the release of per- and polyfluorinated alkyl substances (PFAS) into the environment. In our study we investigated wastewater effluent and mixed liquor samples for PFAS in order to obtain information on the current PFAS contamination in municipal WWTPs in Bavaria, Germany. In addition to PFAS target analysis, the total oxidizable precursor (TOP) assay was used as a PFAS sum parameter to obtain information on the precursor concentration in the samples. The sewersheds of the investigated wastewater treatment plants were characterized according to the industrial sectors that discharge into the public sewer system using the Statistical Classification of Economic Activities in the European Community (NACE) code. Known PFAS were detected in all effluent samples, except one, and in concentrations up to 4.700 ng L<sup>-1</sup>. The concentrations in effluent samples varied widely between the different sampling dates at the individual WWTPs and also between the different WWTPs. The PFAS concentration in the effluent of 65 % of the WWTPs investigated increased significantly by a factor of 2.9 on average after the TOP assay. In the mixed liquor samples, the PFAS concentration ranged between 56 and 440 μg kg<sup>-1</sup> dw. The concentration varied less than in the effluent samples. After the TOP assay the PFAS concentration in the mixed liquor samples increased on average by a factor of 4. The NACE codes alone cannot be used to determine whether low or high PFAS concentrations are to be expected in a municipal WWTP. However, they can provide an indication of PFAS dischargers and help to prioritize further investigations. Without the TOP assay, the PFAS concentration in the effluent and the mixed liquor samples is clearly underestimated. Our investigations identified hotspots with very high PFAS concentrations in the WWTP effluents. Measures must be taken at the sources to prevent the further release of PFAS into the environment via municipal WWTPs.

Authors

Institutions

Publication Details

Journal
Chemosphere
Published
2025-08-08
DOI
https://doi.org/10.1016/j.chemosphere.2025.144612
Citations
2
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
1.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PFAS screening in municipal wastewater effluents and mixed liquor – using TOP assay as a sum parameter

Michael Gierig, Thomas Letzel, H Ulrich, Jörg E. Drewes et al.
2 citations
Chemosphere
Per- and polyfluoroalkyl substances research
1.72
article

PFAS screening in municipal wastewater effluents and mixed liquor – using TOP assay as a sum parameter

Michael Gierig, Thomas Letzel, H Ulrich, Jörg E. Drewes, A-S Heldele
article en
2 citations

Abstract

Wastewater treatment plants (WWTPs) are a point source for the release of per- and polyfluorinated alkyl substances (PFAS) into the environment. In our study we investigated wastewater effluent and mixed liquor samples for PFAS in order to obtain information on the current PFAS contamination in municipal WWTPs in Bavaria, Germany. In addition to PFAS target analysis, the total oxidizable precursor (TOP) assay was used as a PFAS sum parameter to obtain information on the precursor concentration in the samples. The sewersheds of the investigated wastewater treatment plants were characterized according to the industrial sectors that discharge into the public sewer system using the Statistical Classification of Economic Activities in the European Community (NACE) code. Known PFAS were detected in all effluent samples, except one, and in concentrations up to 4.700 ng L<sup>-1</sup>. The concentrations in effluent samples varied widely between the different sampling dates at the individual WWTPs and also between the different WWTPs. The PFAS concentration in the effluent of 65 % of the WWTPs investigated increased significantly by a factor of 2.9 on average after the TOP assay. In the mixed liquor samples, the PFAS concentration ranged between 56 and 440 μg kg<sup>-1</sup> dw. The concentration varied less than in the effluent samples. After the TOP assay the PFAS concentration in the mixed liquor samples increased on average by a factor of 4. The NACE codes alone cannot be used to determine whether low or high PFAS concentrations are to be expected in a municipal WWTP. However, they can provide an indication of PFAS dischargers and help to prioritize further investigations. Without the TOP assay, the PFAS concentration in the effluent and the mixed liquor samples is clearly underestimated. Our investigations identified hotspots with very high PFAS concentrations in the WWTP effluents. Measures must be taken at the sources to prevent the further release of PFAS into the environment via municipal WWTPs.

ChemosphereVol. 386
German Environment Agency (DE), Bifa Umweltinstitut (DE), Technical University of Munich (DE)
Bayerisches Staatsministerium für Umwelt und Verbraucherschutz
Clean water and sanitation
Openalex Percentile: Top 16%
Per- and polyfluoroalkyl substances research
1.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.