Biomechanics of humeral locking plate augmented with fibular strut allograft and intramedullary strut plate using finite element analysis

A humeral locking plate augmented with fibular strut allograft treated for proximal humeral fracture without internal structural support is satisfactory. While it is better clinically and biomechanically than the locking plate alone, it has disadvantages, including difficulty to obtain and the possibility of infection. Other alternative augmentation approaches are in demand. Therefore, the hypothesis of this study is whether intramedullary strut plate can replace fibular strut allograft as a surgical method while providing similar biomechanical performance. The finite element analysis (FEA) models were established based on three-dimensional computed tomography images. Computer-aided design implants were incorporated into the models. According to different implants, models were divided into four groups: the intact humerus, humeral locking plate alone (LP), humeral locking plate augmented with fibular strut allograft (FA), and humeral locking plate augmented with intramedullary strut plate (IMP). The displacements and von Mises stresses were measured on the models by simulating axial force, oblique force and torsion. Compared with the LP group, the displacements and von Mises stresses on the humerus and humeral locking plate in the FA, and IMP groups were all smaller in axial force, oblique force, and torsion. The biomechanical effects of FA and IMP in proximal humeral fracture without internal structural support were basically similar in terms of axial force, oblique force, and torsion. Findings provide useful new ideas for implant design. Our FEA simulation indicates that both the fibular strut allograft (FA) and intramedullary strut plate (IMP) offer similar biomechanical stability in treating proximal humeral fractures without internal structural support. This supports the hypothesis that the intramedullary strut plate can effectively replace the fibular strut allograft.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-08-09
DOI
https://doi.org/10.1038/s41598-025-09848-5
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanics of humeral locking plate augmented with fibular strut allograft and intramedullary strut plate using finite element analysis

Li‐Kun Hung, Kuo‐Chih Su, Cheng‐Hung Lee, Yu-Chun Yen
Scientific Reports
Shoulder Injury and Treatment
article

Biomechanics of humeral locking plate augmented with fibular strut allograft and intramedullary strut plate using finite element analysis

Li‐Kun Hung, Kuo‐Chih Su, Cheng‐Hung Lee, Yu-Chun Yen
article en

Abstract

A humeral locking plate augmented with fibular strut allograft treated for proximal humeral fracture without internal structural support is satisfactory. While it is better clinically and biomechanically than the locking plate alone, it has disadvantages, including difficulty to obtain and the possibility of infection. Other alternative augmentation approaches are in demand. Therefore, the hypothesis of this study is whether intramedullary strut plate can replace fibular strut allograft as a surgical method while providing similar biomechanical performance. The finite element analysis (FEA) models were established based on three-dimensional computed tomography images. Computer-aided design implants were incorporated into the models. According to different implants, models were divided into four groups: the intact humerus, humeral locking plate alone (LP), humeral locking plate augmented with fibular strut allograft (FA), and humeral locking plate augmented with intramedullary strut plate (IMP). The displacements and von Mises stresses were measured on the models by simulating axial force, oblique force and torsion. Compared with the LP group, the displacements and von Mises stresses on the humerus and humeral locking plate in the FA, and IMP groups were all smaller in axial force, oblique force, and torsion. The biomechanical effects of FA and IMP in proximal humeral fracture without internal structural support were basically similar in terms of axial force, oblique force, and torsion. Findings provide useful new ideas for implant design. Our FEA simulation indicates that both the fibular strut allograft (FA) and intramedullary strut plate (IMP) offer similar biomechanical stability in treating proximal humeral fractures without internal structural support. This supports the hypothesis that the intramedullary strut plate can effectively replace the fibular strut allograft.

Scientific ReportsVol. 15(1)
National Chung Hsing University (TW), Taichung Veterans General Hospital (TW), Chung Shan Hospital (TW), Hungkuang University (TW)
Taichung Veterans General Hospital, National Science and Technology Council, U.S. National Library of Medicine
Openalex Percentile: Top 67%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.