STUDY OF STANDART SAMPLES TESTED FOR Au AND Ag CONTENT FOR USE IN NEUTRON-ACTIVATION ANALYSES BY THE RELATIVE METHOD

The article presents the results of the study of the content and distribution of Au and Ag in the available standard samples (CRMs.). The studies were carried out by the method of instrumental neutron activation analysis (INAA) for Au and Ag by multiple parallel small samples (mass 100 mg). In addition, by X-ray fluorescence analysis (XRF) on energy dispersive spectrometer the Ag content in large (7-10 g) samples was studied. The results of statistical processing of parallel measurements are given, the convergence of the results for 100 mg suspensions separately for each defined element is studied. Comparison of used instrumental methods for determination of Ag is carried out. Quality control for each method is given. The limits of application of these CRMs for use in the INAA method are determined.

Authors

Institutions

Publication Details

Journal
NNC RK Bulletin
Published
2025-07-14
DOI
https://doi.org/10.52676/1729-7885-2025-2-125-131
Primary Topic
Nuclear Physics and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

STUDY OF STANDART SAMPLES TESTED FOR Au AND Ag CONTENT FOR USE IN NEUTRON-ACTIVATION ANALYSES BY THE RELATIVE METHOD

S. G. Lennik, E. K. Sokolenko, К. A. Bedelbekova, I. Yu. Silachev et al.
NNC RK Bulletin
Nuclear Physics and Applications
article

STUDY OF STANDART SAMPLES TESTED FOR Au AND Ag CONTENT FOR USE IN NEUTRON-ACTIVATION ANALYSES BY THE RELATIVE METHOD

S. G. Lennik, E. K. Sokolenko, К. A. Bedelbekova, I. Yu. Silachev, S. K. Ydyrysheva
article en

Abstract

The article presents the results of the study of the content and distribution of Au and Ag in the available standard samples (CRMs.). The studies were carried out by the method of instrumental neutron activation analysis (INAA) for Au and Ag by multiple parallel small samples (mass 100 mg). In addition, by X-ray fluorescence analysis (XRF) on energy dispersive spectrometer the Ag content in large (7-10 g) samples was studied. The results of statistical processing of parallel measurements are given, the convergence of the results for 100 mg suspensions separately for each defined element is studied. Comparison of used instrumental methods for determination of Ag is carried out. Quality control for each method is given. The limits of application of these CRMs for use in the INAA method are determined.

NNC RK Bulletin(2)
Institute of Nuclear Physics (UZ)
Affordable and clean energy
Openalex Percentile: Top 73%
Nuclear Physics and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.