Power-Driven Electroporation Is Predictive of Treatment Outcomes in a Conductivity-Independent Manner

<b>Objective:</b> This study characterizes the effects of external conductivity on electroporation to develop methods to overcome potential patient-to-patient variability. <b>Impact Statement:</b> We demonstrate that constant power pulsed electric fields (PEFs) achieve consistent treatment outcomes despite variations in conductivity, thereby improving the predictability and efficacy of electroporation-based therapies. <b>Introduction:</b> Electropermeabilization-based therapies typically deliver static voltages between electrodes to induce cell permeabilization. However, tissue conductivity variations introduce uncertainty in treatment outcomes, as the tissue-specific electric field thresholds that induce electroporation also depend on the extracellular conductivity. <b>Methods:</b> Cell-laden hydrogels were fabricated with varying extracellular conductivities and treated with constant voltage PEFs. The voltages and currents were recorded to calculate the applied powers, and the reversible and irreversible electroporation thresholds were quantified using cell-impermeant and viability assays. Homogeneous and heterogeneous multi-tissue finite element models were employed to simulate the impact of tumor conductivity variability on the outcomes of reversible and irreversible electroporation for constant applied voltage, current, and power PEFs. Additionally, an in vivo murine pancreatic tumor model assessed the correlation between PEF delivery and treatment efficacy. <b>Results:</b> The In vitro experiments revealed that the electric field and current density thresholds were conductivity dependent, whereas the power density thresholds remained stable under variable conductivities. Computational modeling indicated that constant power PEFs best predicted tumor coverage in both homogeneous and heterogeneous multi-tissue models. Similarly, the in vivo tumor responses were also better predicted by applied power rather than voltage or current alone. <b>Conclusions:</b> Applying constant power PEFs enables consistent electroporation outcomes despite variations in conductivity.

Authors

Institutions

Publication Details

Journal
BME Frontiers
Published
2025-01-01
DOI
https://doi.org/10.34133/bmef.0169
Citations
8
Primary Topic
Microbial Inactivation Methods
Type
article
Field-Weighted Citation Impact
9.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Power-Driven Electroporation Is Predictive of Treatment Outcomes in a Conductivity-Independent Manner

Irving C. Allen, Rafael V. Davalos, Edward J. Jacobs, Julio P. Arroyo et al.
8 citations
BME Frontiers
Microbial Inactivation Methods
9.86
article

Power-Driven Electroporation Is Predictive of Treatment Outcomes in a Conductivity-Independent Manner

Irving C. Allen, Rafael V. Davalos, Edward J. Jacobs, Julio P. Arroyo, Pedro Santos, Manali Powar
article en
8 citations

Abstract

<b>Objective:</b> This study characterizes the effects of external conductivity on electroporation to develop methods to overcome potential patient-to-patient variability. <b>Impact Statement:</b> We demonstrate that constant power pulsed electric fields (PEFs) achieve consistent treatment outcomes despite variations in conductivity, thereby improving the predictability and efficacy of electroporation-based therapies. <b>Introduction:</b> Electropermeabilization-based therapies typically deliver static voltages between electrodes to induce cell permeabilization. However, tissue conductivity variations introduce uncertainty in treatment outcomes, as the tissue-specific electric field thresholds that induce electroporation also depend on the extracellular conductivity. <b>Methods:</b> Cell-laden hydrogels were fabricated with varying extracellular conductivities and treated with constant voltage PEFs. The voltages and currents were recorded to calculate the applied powers, and the reversible and irreversible electroporation thresholds were quantified using cell-impermeant and viability assays. Homogeneous and heterogeneous multi-tissue finite element models were employed to simulate the impact of tumor conductivity variability on the outcomes of reversible and irreversible electroporation for constant applied voltage, current, and power PEFs. Additionally, an in vivo murine pancreatic tumor model assessed the correlation between PEF delivery and treatment efficacy. <b>Results:</b> The In vitro experiments revealed that the electric field and current density thresholds were conductivity dependent, whereas the power density thresholds remained stable under variable conductivities. Computational modeling indicated that constant power PEFs best predicted tumor coverage in both homogeneous and heterogeneous multi-tissue models. Similarly, the in vivo tumor responses were also better predicted by applied power rather than voltage or current alone. <b>Conclusions:</b> Applying constant power PEFs enables consistent electroporation outcomes despite variations in conductivity.

BME FrontiersVol. 6
Georgia Institute of Technology (US), Emory University (US), The Wallace H. Coulter Department of Biomedical Engineering (US), Virginia–Maryland College of Veterinary Medicine (US)
Openalex Percentile: Top 2%
Microbial Inactivation Methods
9.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.