A 55-nm SRAM Chip Scanning Errors Every 125 ns for Event-Wise Soft Error Measurement

We developed a 55 nm CMOS static random access memory (SRAM) chip that scans all data every 125 ns and outputs timestamped soft error data via an SPI interface through a FIFO. The proposed system, consisting of the developed chip and particle detectors, enables event-wise soft error measurement and precise identification of single bit upset and multiple-cell upsets (MCUs), thus resolving misclassifications such as Pseudo- and Distant MCUs that conventional methods cannot distinguish. An 80-MeV proton irradiation experiment at RARiS, Tohoku University verified the system operation. Timestamps between the SRAM chip and the particle detectors were successfully synchronized, accounting for PLL disturbances caused by radiation. Event building was achieved by determining a reset offset with sub-ns resolution, and spatial synchronization was maintained within several tens of micrometers.

Authors

Institutions

Publication Details

Journal
IEEE Solid-State Circuits Letters
Published
2025-01-01
DOI
https://doi.org/10.1109/lssc.2025.3589611
Primary Topic
Radiation Effects in Electronics
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A 55-nm SRAM Chip Scanning Errors Every 125 ns for Event-Wise Soft Error Measurement

Masanori Hashimoto, Satoshi Adachi, Waleed Madany, Akira Sato et al.
IEEE Solid-State Circuits Letters
Radiation Effects in Electronics
article

A 55-nm SRAM Chip Scanning Errors Every 125 ns for Event-Wise Soft Error Measurement

Masanori Hashimoto, Satoshi Adachi, Waleed Madany, Akira Sato, Kenichi Okada, Yuibi Gomi, Masatoshi Itoh
article en

Abstract

We developed a 55 nm CMOS static random access memory (SRAM) chip that scans all data every 125 ns and outputs timestamped soft error data via an SPI interface through a FIFO. The proposed system, consisting of the developed chip and particle detectors, enables event-wise soft error measurement and precise identification of single bit upset and multiple-cell upsets (MCUs), thus resolving misclassifications such as Pseudo- and Distant MCUs that conventional methods cannot distinguish. An 80-MeV proton irradiation experiment at RARiS, Tohoku University verified the system operation. Timestamps between the SRAM chip and the particle detectors were successfully synchronized, accounting for PLL disturbances caused by radiation. Event building was achieved by determining a reset offset with sub-ns resolution, and spatial synchronization was maintained within several tens of micrometers.

IEEE Solid-State Circuits LettersVol. 8
Tohoku University (JP), Kyoto University (JP), Institute of Science Tokyo (JP), The University of Osaka (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 82%
Radiation Effects in Electronics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.