A 55-nm SRAM Chip Scanning Errors Every 125 ns for Event-Wise Soft Error Measurement
We developed a 55 nm CMOS static random access memory (SRAM) chip that scans all data every 125 ns and outputs timestamped soft error data via an SPI interface through a FIFO. The proposed system, consisting of the developed chip and particle detectors, enables event-wise soft error measurement and precise identification of single bit upset and multiple-cell upsets (MCUs), thus resolving misclassifications such as Pseudo- and Distant MCUs that conventional methods cannot distinguish. An 80-MeV proton irradiation experiment at RARiS, Tohoku University verified the system operation. Timestamps between the SRAM chip and the particle detectors were successfully synchronized, accounting for PLL disturbances caused by radiation. Event building was achieved by determining a reset offset with sub-ns resolution, and spatial synchronization was maintained within several tens of micrometers.
Authors
- Masanori Hashimoto (ORCID: https://orcid.org/0000-0002-0377-2108)
- Satoshi Adachi (ORCID: https://orcid.org/0000-0002-8454-3971)
- Waleed Madany (ORCID: https://orcid.org/0000-0002-5653-9983)
- Akira Sato (ORCID: https://orcid.org/0000-0002-3617-8121)
- Kenichi Okada (ORCID: https://orcid.org/0000-0002-1082-7672)
- Yuibi Gomi
- Masatoshi Itoh
Institutions
- Tohoku University (JP)
- Kyoto University (JP)
- Institute of Science Tokyo (JP)
- The University of Osaka (JP)
Publication Details
- Journal
- IEEE Solid-State Circuits Letters
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1109/lssc.2025.3589611
- Primary Topic
- Radiation Effects in Electronics
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Japan Society for the Promotion of Science