Optimal D-STATCOM Operation in Power Distribution Systems to Minimize Energy Losses and CO2 Emissions: A Master–Slave Methodology Based on Metaheuristic Techniques

In this paper, we address the problem of intelligent operation of Distribution Static Synchronous Compensators (D-STATCOMs) in power distribution systems to reduce energy losses and CO2 emissions while improving system operating conditions. In addition, we consider the entire set of constraints inherent in the operation of such networks in an environment with D-STATCOMs. To solve such a problem, we used three master–slave methodologies based on sequential programming methods. In the proposed methodologies, the master stage solves the problem of intelligent D-STATCOM operation using the continuous versions of the Monte Carlo (MC) method, the population-based genetic algorithm (PGA), and the Particle Swarm Optimizer (PSO). The slave stage, for its part, evaluates the solutions proposed by the algorithms to determine their impact on the objective functions and constraints representing the problem. This is accomplished by running an Hourly Power Flow (HPF) based on the method of successive approximations. As test scenarios, we employed the 33- and 69-node radial test systems, considering data on power demand and CO2 emissions reported for the city of Medellín in Colombia (as documented in the literature). Furthermore, a test system was adapted in this work to the demand characteristics of a feeder located in the city of Talca in Chile. This adaptation involved adjusting the conductors and voltage limits to include a test system with variations in power demand due to seasonal changes throughout the year (spring, winter, autumn, and summer). Demand curves were obtained by analyzing data reported by the local network operator, i.e., Compañía General de Electricidad. To assess the robustness and performance of the proposed optimization approach, each scenario was simulated 100 times. The evaluation metrics included average solution quality, standard deviation, and repeatability. Across all scenarios, the PGA consistently outperformed the other methods tested. Specifically, in the 33-node system, the PGA achieved a 24.646% reduction in energy losses and a 0.9109% reduction in CO2 emissions compared to the base case. In the 69-node system, reductions reached 26.0823% in energy losses and 0.9784% in CO2 emissions compared to the base case. Notably, in the case of the Talca feeder—particularly during summer, the most demanding season—the PGA yielded the most significant improvements, reducing energy losses by 33.4902% and CO2 emissions by 1.2805%. Additionally, an uncertainty analysis was conducted to validate the effectiveness and robustness of the proposed optimization methodology under realistic operating variability. A total of 100 randomized demand profiles for both active and reactive power were evaluated. The results demonstrated the scalability and consistent performance of the proposed strategy, confirming its effectiveness under diverse and practical operating conditions.

Authors

Institutions

Publication Details

Journal
Sci
Published
2025-07-11
DOI
https://doi.org/10.3390/sci7030098
Primary Topic
Optimal Power Flow Distribution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal D-STATCOM Operation in Power Distribution Systems to Minimize Energy Losses and CO2 Emissions: A Master–Slave Methodology Based on Metaheuristic Techniques

Luis Fernando Grisales-Noreña, Jesús C. Hernández, Rubén Iván Bolaños, Oscar Danilo Montoya et al.
Sci
Optimal Power Flow Distribution
article

Optimal D-STATCOM Operation in Power Distribution Systems to Minimize Energy Losses and CO2 Emissions: A Master–Slave Methodology Based on Metaheuristic Techniques

Luis Fernando Grisales-Noreña, Jesús C. Hernández, Rubén Iván Bolaños, Oscar Danilo Montoya, Cristopher Enrique Torres-Mancilla
article en

Abstract

In this paper, we address the problem of intelligent operation of Distribution Static Synchronous Compensators (D-STATCOMs) in power distribution systems to reduce energy losses and CO2 emissions while improving system operating conditions. In addition, we consider the entire set of constraints inherent in the operation of such networks in an environment with D-STATCOMs. To solve such a problem, we used three master–slave methodologies based on sequential programming methods. In the proposed methodologies, the master stage solves the problem of intelligent D-STATCOM operation using the continuous versions of the Monte Carlo (MC) method, the population-based genetic algorithm (PGA), and the Particle Swarm Optimizer (PSO). The slave stage, for its part, evaluates the solutions proposed by the algorithms to determine their impact on the objective functions and constraints representing the problem. This is accomplished by running an Hourly Power Flow (HPF) based on the method of successive approximations. As test scenarios, we employed the 33- and 69-node radial test systems, considering data on power demand and CO2 emissions reported for the city of Medellín in Colombia (as documented in the literature). Furthermore, a test system was adapted in this work to the demand characteristics of a feeder located in the city of Talca in Chile. This adaptation involved adjusting the conductors and voltage limits to include a test system with variations in power demand due to seasonal changes throughout the year (spring, winter, autumn, and summer). Demand curves were obtained by analyzing data reported by the local network operator, i.e., Compañía General de Electricidad. To assess the robustness and performance of the proposed optimization approach, each scenario was simulated 100 times. The evaluation metrics included average solution quality, standard deviation, and repeatability. Across all scenarios, the PGA consistently outperformed the other methods tested. Specifically, in the 33-node system, the PGA achieved a 24.646% reduction in energy losses and a 0.9109% reduction in CO2 emissions compared to the base case. In the 69-node system, reductions reached 26.0823% in energy losses and 0.9784% in CO2 emissions compared to the base case. Notably, in the case of the Talca feeder—particularly during summer, the most demanding season—the PGA yielded the most significant improvements, reducing energy losses by 33.4902% and CO2 emissions by 1.2805%. Additionally, an uncertainty analysis was conducted to validate the effectiveness and robustness of the proposed optimization methodology under realistic operating variability. A total of 100 randomized demand profiles for both active and reactive power were evaluated. The results demonstrated the scalability and consistent performance of the proposed strategy, confirming its effectiveness under diverse and practical operating conditions.

SciVol. 7(3)
University of Talca (CL), Universidad de Jaén (ES), Universidad Distrital Francisco José de Caldas (CO), Instituto Tecnológico Metropolitano (CO), University of Córdoba (ES), Universidad del Valle (CO)
Fondo Nacional de Ciencia Tecnología e Innovación
Affordable and clean energy
Openalex Percentile: Top 82%
Optimal Power Flow Distribution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.