Can Side Holes in Returning Cannula Improve VV-ECMO Effectiveness?

Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving therapy used for patients with respiratory failure; however, its effectiveness may be compromised by high recirculation rates. Recirculation occurs when oxygenated blood from the returning cannula is drawn back into the ECMO circuit by the drainage cannula. In this study, we compared the recirculation rates between a returning cannula with 2 and 12 side holes for ECMO flow of 4 L/min using computational modeling of blood flow and oxygen diffusion. Simulations were computed using a patient-specific model of the right atrium, superior and inferior vena cava derived from the CT scan. For both cannulas, the recirculation rate was 12% and oxygen saturation was 86%, suggesting negligible influence of side holes on VV-ECMO efficacy. Further studies are needed to assess whether different designs could improve VV-ECMO performance. The pipeline used here can be used to evaluate and optimize such designs.

Authors

Institutions

Publication Details

Published
2025-06-02
DOI
https://doi.org/10.23919/measurement66999.2025.11078673
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Can Side Holes in Returning Cannula Improve VV-ECMO Effectiveness?

Beáta Ondrušová, Jens Meier, Johannes Szasz, Argyrios Petras et al.
Mechanical Circulatory Support Devices
article

Can Side Holes in Returning Cannula Improve VV-ECMO Effectiveness?

Beáta Ondrušová, Jens Meier, Johannes Szasz, Argyrios Petras, Luca Gerardo‐Giorda
article en

Abstract

Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving therapy used for patients with respiratory failure; however, its effectiveness may be compromised by high recirculation rates. Recirculation occurs when oxygenated blood from the returning cannula is drawn back into the ECMO circuit by the drainage cannula. In this study, we compared the recirculation rates between a returning cannula with 2 and 12 side holes for ECMO flow of 4 L/min using computational modeling of blood flow and oxygen diffusion. Simulations were computed using a patient-specific model of the right atrium, superior and inferior vena cava derived from the CT scan. For both cannulas, the recirculation rate was 12% and oxygen saturation was 86%, suggesting negligible influence of side holes on VV-ECMO efficacy. Further studies are needed to assess whether different designs could improve VV-ECMO performance. The pipeline used here can be used to evaluate and optimize such designs.

Johannes Kepler University of Linz (AT), Kepler Universitätsklinikum (AT), Johann Radon Institute for Computational and Applied Mathematics (AT)
Openalex Percentile: Top 81%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.